SPECIFICATIONS

SubDrive 30 Connect/SubDrive 50 Connect

SubDrive 30 Connect/SubDrive 50 Connect
NEMA 3R
Model
(indoor/outdoor)
Voltage
Phase In
Frequency
Current (max)
Input from
Power Factor
Power Source
Power (idle)
Power (max)
Wire Gauge Size(s)
Voltage
Phase Out
Frequency Range
Output to
Motor
Current (max)
Wire Gage Size(s)
Factory Preset
Pressure
Setting
Adjustment Range
Temperature
Operating
(at 230 VAC input)
Conditions*
Relative Humidity
Temperature
Storage**
Shelf Life
Dimensions
NEMA 3R
and Weight
* Operating temperature is specified at full output power when installed as recommended. Refer to
Temperature Foldback" on page
** Shelf life can be extended for one year by powering the drive for 60 minutes with no load.
48
SubDrive 30
5870205403C
208/230 ± 10% VAC
Single-Phase
60/50 Hz
23 A
~ 0.95
5 Watts
4.2 kW
"Input Wire and Fuse Sizing" on
Refer to
page 18
.
272 VAC Maximum
Single-Phase (3-Wire) OR Three-Phase
30-78 Hz: 1/2-rated pump (Three-Phase)
30-70 Hz: 2/3 or 3/4-rated pump (Three-Phase)
30-60 Hz: Matched pump (Three-Phase)
30-63 Hz (Single-Phase Motors)
10.9 A / phase
"Output (Motor) Wire Sizing" on
Refer to
page 18
.
50 psi (3.4 bar)
Transducer: 5-95 psi (0.3-6.6 bar)
Pressure Sensor: 25-80 psi (1.7-5.5 bar)
–13 °F to 122 °F (–25 °C to 50 °C)
20-95%, non-condensing
–13 °F to 149 °F (–25 °C to 65 °C)
1.5 Years
9-3/4" x 19-3/4" x 5-1/4" : 26 lbs
(25 x 50 x 13 cm) : (11.8 kg)
30.
SubDrive 50
5870205503C
208/230 ± 10% VAC
Single-Phase
60/50 Hz
36 A
~ 0.95
7 Watts
7.2 kW
"Input Wire and Fuse Sizing" on
Refer to
page 18
.
272 VAC Maximum
Single-Phase (3-Wire) OR Three-Phase
30-78 Hz: 1/2-rated pump (Three-Phase)
30-70 Hz: 2/3 or 3/4-rated pump (Three-Phase)
30-60 Hz: Matched pump (Three-Phase)
30-63 Hz (Single-Phase Motors)
17.8 A (three-phase), 17.0 A (single-phase)
"Output (Motor) Wire Sizing" on
Refer to
page 18
.
50 psi (3.4 bar)
Transducer: 5-95 psi (0.3-6.6 bar)
Pressure Sensor: 25-80 psi (1.7-5.5 bar)
–13 °F to 122 °F (–25 °C to 50 °C)
20-95%, non-condensing
–13 °F to 149 °F (–25 °C to 65 °C)
1.5 Years
9-1/8" x 15-3/8" x 11-1/2" : 31 lbs
(66 x 39 x 29 cm) : (14.1 kg)