9.4.2
Container change with the preset (acknowledge man.)
Fig. 88: Empty signal: Changing a container
1.
In the operating screen, press the 'empty signal indicator'
2.
If a password prompt is displayed, the access code must be entered
(
Ä Chapter 7.7.2 'Open the main menu with the access code activated'
on page 68).
ð The screen switches to the information screen for the 'empty signal' .
3.
Performing a container change:
- Remove the suction pipe from the empty container.
- Replace the empty container with a full container.
- Place the suction pipe back into the full container.
ð The pump detects the new fill level via the connected suction pipe.
4.
Following a detected container change, the pump automatically resumes operation
with the last settings.
To access the settings, press and hold the displayed 'empty signal' for
around 3 seconds.
DANGER!
It is essential that the personal protective equipment (PPE) described on
the product data sheet (safety data sheet) for the metering medium is
used.
WARNING!
Risk of slipping due to fluid in the operation and provisioning area!
– Wear non-slip, chemically resistant shoes when working.
– Place product containers in a tank to prevent a slipping hazard caused
by leaking fluids.
ENVIRONMENT!
Immediately soak up any leaking liquids with a suitable binding agent and
dispose of properly.
135
Operation
.
417102276 Rev. 3-01.2019