6.2 - Level two programming (adjustable parameters)

All level 2 parameters are set by default as highlighted in grey in Table 7, and
may be modified at any time as explained in Table 8.
The parameters can be set on a scale from 1 to 8. To check the value corre-
sponding to each LED see Table 7.
Input LED
Parameter
L1
Time
Pause
L2
Function
Step by
step
L3
Speed
Motor
L4
Output
FLASH
8 – English
TABLE 6 - First level functions
Example
This function performs automatic closure of the pole after the programmed pause time. Factory setting:
30 seconds. Value programmable from 5 to 200 seconds.
This function enables the pole to remain in Opening position for the time required for transit. When the function is
active, operation depends on the parameter set in the function "Automatic closure":
• with "Automatic closure" active, the Opening manoeuvre stops immediately after the photocells are disengaged
and the Closure manoeuvre starts after 5 seconds.
• with "Automatic closure" not active, the pole always reaches the maximum Opening position (even if the
photocells are disengaged beforehand) and Closure starts after 5 seconds.
This function is useful in the event of a power failure, even brief. In fact if this function is active(ON), when power is
restored, the control unit detects the pole as open and starts Closure. For reasons of safety the Closure manoeuvre
is preceded by a 3-second pre-flashing interval.
The Stand-by function allows consumptions to be reduced. If active, 1 minute after the end of the manoeuvre, the
control unit turns off the "Bluebus" output (connected devices) and all the LEDs apart from the Bluebus LED which
will flash more slowly. When the control unit receives a command normal operation is restored. When using X-Bar
with the Solemyo system, a longer Stand By mode must be set. This operation is performed using the Oview
programmer.
This function enables the user to double the space for starting deceleration, both in Opening and Closing. If the
function is deactivated, deceleration is short.
This function activates a pause of 3 seconds between activation of the flashing light and the start of a manoeuvre.
When this function is set to "ON" the level of control unit sensitivity in obstacle detection can be increased
considerably. If used as a means to read the "impact force" of the motor, the values "speed" and "motor force"
must be set accordingly in the level 2 menu.
This parameter enables inversion of the direction of motor rotation to enable barrier installation on the right; the
factory setting is "OFF" (standard motor rotation – pole closure on left).
Important – If the function is activated, the Opening and Closing positions must be memorised again (Paragraph 4.5).
TABLE 7 - Second level functions
LED (level)
Value
L1
5 seconds
L2
10 seconds
L3
20 seconds
L4
40 seconds
L5
60 seconds
L6
80 seconds
L7
120 seconds
L8
200 seconds
L1
Open – stop – close - stop
L2
Open – stop – close - open
L3
Open – close – open - close
L4
Apartment block (more than 2 sec. generates Stop)
L5
Apartment block 2 (less than 2 sec. generates partial opening).
L6
Step by step 2
L7
Hold-to-run
L8
Opening in semi-automatic mode, closing in dead man mode
L1
Speed 1 (30% - slow)
L2
Speed 2 (47%)
L3
Speed 3 (65%)
L4
Speed 4 (82%)
L5
Speed 5 (100%) - fast
L6
Open V3, Close V2
L7
Open V4, Close V3
L8
Open V5, Close V4
L1
Pole Open Indicator Function (24 V - 10 W)
L2
Active if pole closed (24 V - 10 W)
L3
Active if pole open(24 V - 10 W)
L4
Flashing light(12 V - 21 W)
L5
Flashing light for pole lights (24 V - 10 W)
L6
Electric lock(24 V - 10 W)
L7
Suction cup(24 V - 10 W)
L8
Maintenance indicator (24 V - 10 W)
IMPORTANT – In the programming procedure, the maximum time interval that
can elapse between activation of one key and the next is 10 seconds. When
this time elapses, the procedure terminates automatically, memorising the
modifications made up until then.
Description
Sets the pause time, i.e. the time that
passes between the end of an ope-
ning manoeuvre and the start of an
automatic closing manoeuvre
This parameter is only effective if the
"automatic Closure" is active.
Sets the sequence of commands as-
sociated with the input or the radio
control: "Step by step".
Sets the motor speed during normal
travel.
Selects the type of device connected
to the FLASH output.
Important! – If the programmed set-
ting is modified, check the type of vol-
tage of the new device connected to
the FLASH terminal and ensure that it
corresponds to the type of voltage of
the selected programming level.