PRODUCT DISPOSAL
This product is an integral part of the automation system it controls and
must be disposed of along with it.
As in the case of installation, likewise at the end of product lifetime the disas-
sembly and scrapping operations must be performed by qualified personnel.
This product is made of various types of material, some of which can be recy-
cled while others must be scrapped. Seek information on the recycling and dis-
posal methods envisaged by the local regulations in your area for this product
category.
Caution! – Some parts of the product may contain polluting or hazardous sub-
stances which, if released to the environment, may cause serious damage to
the environment or to human health.
As indicated by the symbol alongside, disposal of this prod-
uct with domestic waste is strictly prohibited. Separate the
waste into categories for disposal, according to the methods
established by current legislation in your area, or return the
product to the retailer when purchasing a new version.
WARNINGS: • All technical specifications stated in this section refer to an ambient temperature of 20°C (± 5°C). • Nice S.p.a. reserves the right to apply modifi-
cations to products at any time when deemed necessary, maintaining the same intended use and functionality.
Product Type
Maximum torque on start-up
Nominal torque
Maximum operating
cycle frequency
at nominal torque *
Maximum continuous operating
time at nominal torque **
Opening time
Durability
Peak power supply
Peak power absorption on start-up
Maximum power at nominal torque
Insulation class
Emergency power supply
Courtesy light
Flashing light output
BLUEBUS output
STOP Input
S.S. input
OPEN Input
CLOSE Input
Radio AERIAL input
Radio connector
Programmable functions
Functions in self-learning mode
Operating temperature
Use in particularly acid,
saline or potentially
explosive atmospheres
Protection rating
Dimensions
Weight
Note:
(*) At 50°C the maximum operating frequency is 40 cycles/hour
(**) At 50°C the maximum continuous operating time is 5 minutes.
TECHNICAL CHARACTERISTICS OF THE PRODUCT
X-Bar is an electromechanical road barrier for residential use. Controls opening and closing of
an access point with a maximum width of 3 m. Complete with electronic control unit
between 80,000 and 500,000 manoeuvre cycles according to the conditions stated in Table 2
For 1 flashing light LUCYB, MLB or MLBT (12 V - 21 W lamp)
1 output with maximum load of 12 Bluebus units
For normally closed, normally open or 8.2 kΩ; constant resistance contacts in self-learning mode
(a change from the memorised state prompts the "STOP" command)
For normally open contacts (closure of the contact prompts the Step by Step command)
For normally open contacts (closure of the contact prompts the OPEN command)
For normally open contacts (closure of the contact prompts the CLOSE command)
SM connector for receiver types SMXI, SMXIS or OXI, OXIT and OXIFM
8 ON-OFF type functions and 8 adjustable functions (see tables 6 and 7)
Self-learning of devices connected to the BlueBus output. Self-learning of "STOP"
type devices (contacts NO, NC or 8,2KΩ). resistance). Learning of pole opening and closing positions and
calculation of the points of deceleration and partial opening
1146 x 300 h 179,5; pole: minimum 2 m - maximum 3 m
Caution! – Local legislation may impose heavy fines in the event of illegal dis-
posal of this product.
100 Nm
25 Nm
100 (80 with XBA4 accesory) cycles / hour
10 (8 with XBA4 accesory) minutes
≥ 4 s (>5s with XBA4 accesory)
230 Vac (50/60Hz)
300W
200 W
I
Yes (with PS124 accessory)
12 V / 10 W (BA15S connection)
52 Ω for RG58 or similar type cable
from -20° C to +50° C
No
IP 44
35 Kg