9 - Gearmotor manual release and locking: The gearmotor is
equipped with a mechanical system that enables manual opening and
closing of the pole. These operations are required in the event of a
power failure or malfunctions.
IMPORTANT!
– The gearmotor release and locking operations must be per-
formed only when the pole is horizontal and stationary.
B
18 – English
– The gearmotor can be released manually on both sides of the
barrier.
01. Unscrew the key cover (Fig. B-1);
02. Insert the key supplied and turn through 180° (Fig. B-2);
03. Move the pole as required (Fig. B - 3);
04. To lock the gearmotor, rotate the key through a further 180°.
1
3
0 °
1 8
2
3