Technical Specifications; Troubleshooting - STEINEL PROFESSIONAL IR 180COM1 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35
11� Technical specifications
Dimensions W × H × D
80 × 80 × 50 mm
Supply voltage
220-240 ~V / 50/60 HZ
Sensor system
Passive infrared (IR) / high-frequency (HF)
Reach
IR max. 20 m (tangential) /
max. 4 m (radial) / HF max. 8 m
Angle of coverage
180°
Output
Incandescent / halogen lamp load
Fluorescent lamps, electronic ballast
Fluorescent lamps, uncorrected
Fluorescent lamps, series-corrected
Fluorescent lamps, parallel-corrected
Low-voltage halogen lamps
LED < 2 W
2 W < LED < 8 W
LED > 8 W
Capacitive load
Output, switching
max. 230 W / 230 V
output 2 presence
max. 1 A (cos φ = 1)
(COM 2 only)
for HVAC (heating/ventilation / air-conditioning)
Light-level setting
10-1000 lux, ∞ / daylight
Switching output 1
30 s - 30 min, pulse mode (approx. 2 s),
Time setting, IQ mode time (automatic adjustment to
usage profile)
Switching output 2
Time setting 0 or 10 min switch-ON delay.
only COM2 for HVAC
5-15 min stay-ON time via (RC)
1 min - 2 h stay-ON time via Smart Remote
Automatic room surveillance
Mounting height
1.1 m
Time setting
30 s - 30 min
IP rating
IP20
Temperature range
0°C to 40°C
*
At extreme angles, the reach of the
conditions.
*
2000 W
1000 W
1000 VA
400 VA
500 VA
2000 VA
100 W
300 W
600 W
176 μF
HF 180 is extensively determined by local
- 32 -
12� Troubleshooting
Malfunction
Cause
Light does not switch ON n No supply voltage
n Lux setting too low
n No motion being
detected
Light does not switch OFF n Lux setting too high
n Stay-ON time still
effective
n Interfering heat sources:
e.g. fan heater, open
doors and windows,
pets, light bulb / halo-
gen floodlight, moving
objects
Sensor switches OFF
n Stay-ON time too short
despite persons being
n Light-level threshold too
present
low
Sensor does not switch
n Stay-ON time too long
OFF quickly enough
Sensor does not switch
n Reach is reduced when
ON quickly enough when
approached from the
approached from the front
front
Sensor does not switch
n Lux setting too low
ON when persons are
present despite it being
dark
Switch not working
n Switch deactivated?
Remedy
n Check supply voltage
n Slowly increase lux set-
ting until light switches
ON
n Ensure unobstructed
sensor vision
n Check detection zone
n Reduce lux setting
n Wait until stay-ON time
elapses; reduce stay-
ON time if necessary
n Use stickers to mask
out stationary sources
of interference
n Increase stay-ON time
n Change twilight setting
n Reduce stay-ON time
n Install additional sensors
n Reduce distance
between two sensors
n Sensor deactivated by
switch/button?
n Semi-automatic mode?
n Increase light-level
threshold
n Check DIP switch 3
setting
- 33 -

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ir 180com2Hf 180 com1Hf 180com2Ir 180 com1

Tabla de contenido