KPS-PA50 MINI • Digital clamp meter
• For optimum results, center the conductor in the jaw.
• At the manual range mode, when only 'OL' or '-OL' is shown on the LCD, it
means the measurement has exceeded the range. A higher range should
be selected.
• "
" means the maximum input current is 600A rms DC.

4.12 Measuring frequency

Beware of Electrocution. Ensure that the test leads are disconnected
from the meter before making current clamp measurements.
• Set the rotary selector to the A range ( A or A ) position.
• Press the trigger to open jaw. Fully enclose only one conductor.
• Press the "Hz/%" to switch to the frequency measurement.
• Take the reading on the LCD.
NOTE:
Do not put more than one cable into the jaw during test, otherwise incorrect test
value might be obtained.
Frequency test range is 10Hz - 1kHz. '00.0' will be displayed on LCD if the test
frequency is lower than 10.0 Hz. It is possible to test the frequency which is
higher than 1 kHz but the tolerance of the test result can not be ensure.
4) "
"means the maximum input current is 600A rms AC.
By V range:
Beware of Electrocution. Pay special attention to avoid electric shock
when measuring high voltage. Do not input the voltage which more
than 600V rms AC.
1) Plug the black test lead into the COM jack and the red test lead into the
INPUT jack.
2) Set the rotary selector to the V range position.
3) Press the "Hz/%" to switch to frequency measurement.
4) Connect test leads to the two ends of the source or load for measurement.
5)Take the reading on the LCD.
WARNING
WARNING
43