Inground Spa Manual
5. PROBLEMS AND SOLUTIONS
PROBLEM
No element is activated.
No pump or heating is
activated.
Filter
Low water flow during
filtration.
Filter pump is not activated.
Water Massage
Massage pump is not
activated.
Low air flow in jets.
Water comes out the Venturi
jet.
Air Massage
The massage pump is not
activated.
REASON
Circuit breaker on OFF position.
Operating switch in OFF position.
Obstructed or dirty filter.
Filter pump faulty.
Faulty or poorly connected
contactor.
Poorly regulated thermal magnetic
breaker.
Faulty thermal magnetic breaker.
Pump selector on stop.
Tube* / signal transmission cable
disconnected.
Worn push button air bulb.*
Faulty pump.
Faulty or poorly connected
contactor.
Poorly regulated thermal magnetic
breaker.
Faulty thermal magnetic breaker.
General massage switch on OFF.
Closed and obstructed venturis.
Incorrectly placed jet front
Tube* / signal transmission wire
disconnected.
Worn push button air bulb.*
Faulty pump.
Faulty or poorly connected
contactor.
Badly regulated thermal magnetic
breaker.
Faulty thermal magnetic breaker.
33
SOLUTION
Switch circuit breaker to ON.
Change operating switch to ON.
Wash filter.
Check pump / Change brushes.
Installer: Check connection
wires. Change contactor.
Adjust thermal magnetic breaker
according to motor
consumption.
Change thermal magnetic
breaker.
Change to manual or automatic.
Connect tube* / cable.
Change bulb *.
Check pump / Change brushes.
Installer: Check connection
cables. Change contactor.
Adjust thermal magnetic breaker
according to motor
consumption.
Change thermal magnetic
breaker.
Set switch to ON.
Open Venturis.
Eliminate obstructions
Check jets
Connect the tube * / cable.
Change bulb *.
Check the pump / Change
brushes.
Installer: Check connection
wires. Change contactor.
Adjust thermal magnetic breaker
according to motor
consumption.
Change thermal magnetic
breaker.
EN