dimension detection (where provided) and wheel
balancing
B Machine programs selection
In this way, the operator is able to perform, monitor
and verify the outcome of each wheel balancing
and intervene in case of unforeseen events.
SWITCHING ON THE MA-
CHINE
Connect the power supply cable (A, fig.13) sup-
plied with the machine from the external electri-
cal panel located on the rear side of the wheel
balancer body to the mains.
A
Turn on the machine using the switch located
on the left-hand side of the body. (B, fig.13a).
52
The wheel balancer performs a checking test (all
the LCD display indicators light up and the release
of the installed software is displayed).
If no anomaly is detected, a beeper sounds and
the active initial status is displayed as follows:
12a
- active balancing mode: dynamic;
- values displayed : 000 000;
- unbalance display at 5-g (or 1/4-of-an-ounce)
increments;
- sensor value rounding-off active;
- default geometric values: width= 5.5", diameter
= 14", distance = 150.
- operator 1 active.
Now the operator can set the data of the wheel
to be balanced or select one of the programmes
available.
KEYPAD AND LCD DISPLAY
13
EM 9550 Plus - EM 9550 C Plus - Operator's manual
B
Keypad buttons (fig. 14)
• moves the cursor to the pro-
gramme menu;
• increases the displayed value.
• moves the cursor to the pro-
gramme menu;
• decreases the displayed value.
13a
14