- Select the exit
programme without performing the calibration.
DISPLAY MESSAGES
The machine can recognise a certain number
of malfunction conditions and signals them to
the user by visualising the relevant messages
on the displays.
– A – Notice messages
A 3
wheel not suitable for performing the
sensitivity calibration, use a wheel of
average dimensions (typically 5.5"X14")
or larger but with a weight that does not
exceed 40 kg.
A 5
Dimension settings not correct for an ALU
programme. Correct the set dimensions.
A 7
The machine is not enabled temporarily
to select the programme requested.
Perform a wheel spin, then repeat the
request.
A 10
Internal sensor not in the rest position.
Return the sensor to the rest position
(completely in). If the message does
not disappear, internal sensor operation
can be disabled by pressing the
button
A 20
Ultrasonic sensor calibration template in
an incorrect position during calibration.
Bring it to the position indicated and
repeat the calibration.
A 25
Programme not available on this model.
A 26
Programme available after selecting
one of the following programmes only:
ALU 1P / ALU 2P / Motorcycle Dynamic /
Motorcycle Alu.
A 31
Optimisation procedure (OPT) already
launched by another user.
A 51
Incorrect wheel clamping (only with the
automatic wheel clamping system).
A 52
Hub mounting/demounting procedure
started automatic wheel clamping sys-
tem.
After 30 seconds, the procedure ends
automatically.
A Stp Wheel stop during the spin phase.
A Cr
Spin performed with the guard raised.
Lower the guard to perform the wheel
72
button to exit the
EM 9550 Plus - EM 9550 C Plus - Operator's manual
spin.
– E – Error Messages
E 1
Sensitivity calibration missing.
Perform the sensitivity calibration pro-
cedure.
E 2
Error condition on sensitivity calibration.
Repeat the sensitivity calibration, paying
attention to the first spin, which must
be performed with the wheel like the
subsequent spins.
Take particular care NOT to knock the
machine during calibration.
E 3 I/E 2/3
Error condition at the end of sensitivity
calibration. Repeat the calibration, if the
message persists perform the following
checks:
• Correct sensitivity calibration proce-
dure;
• Correct fastening and position of the
calibration weight;
• Mechanical and geometric condition of
the calibration weight;
• Geometry of the wheel used.
E 4
a) Error condition on ultrasonic sensor
calibration. Calibrate the ultrasonic sen-
sor.
b) ultrasonic sensor not present. Visu-
alisation of this error can be disabled by
performing the following procedure:
-
keep the
least three seconds to access the com-
plete programme menu.
-
use the
the cursor.
-
select the
-
Press the
E 6
Error condition when executing optimisa-
tion programme.
Repeat the procedure from the beginning.
E 12
Ultrasonic width sensor not present or
faulty. Visualisation of this error can be
disabled by performing the following
procedure:
button pressed for at
buttons to move
programme.
button.