Safety Precautions
Installation Pre-check
The Kube's installation kit includes adapters for the most common plumbing configuration.
Confirm your plumbing system uses compression fittings. If not, consult with your local DIY
supplier to determine the fittings you need to properly install the Kube.
Check with your state and local public works department for plumbing and sanitation codes.
Follow these guidelines as you install the Kube Advanced Water Filtration System.
Make sure your water supply conforms to what is specified in the Performance Data. If you don't
know your water conditions, contact your municipal water company.
CAUTION:
Do not use the Kube with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system.
Proper Installation
The Kube Advanced Water Filtration System must be properly located and installed in accordance
with the Installation Instructions before it is used. Follow all steps exactly to correctly install.
For certified performance, install the Kube with a 2.2 GPM rated faucet.
Use the Kube on a potable, safe-to-drink, COLD water supply only. The Kube will not purify water or
make unsafe water safe to drink.
Do not install the Kube outside or anywhere it will be exposed to sunlight.
Protect the Kube and piping from freezing. Water freezing in the system may damage it.
The Kube will withstand up to 125 PSI water pressure.
Do not install on HOT WATER. The temperature of the water supply to the Kube must be between
the minimum of 35°F (2°C) and the maximum of 120°F (49°C).
See the Performance Data section for additional details.
Model No. KUBE14
For cold water use only
Minimum Operating Temp: 35° F
Maximum Operating Temp: 120° F
Minimum Operating Pressure: 35 PSI
Maximum Operating Pressure: 125 PSI
Kube Replacement Filters Model No.: KUBE14F1
To order replacement filters, please visit:
www.kubewater.com