WARNING: REVIEW AND UNDERSTAND ALL OF THE WARNINGS IN THE SAFETY INFORMATION
SECTION. THEY ARE REQUIRED TO OPERATE THIS HEATER SAFELY. FOLLOW ALL LOCAL
AND STATE CODES WHEN OPERATING THIS HEATER.
WARNING: AFTER INSTALLING ALL GAS PIPING, AND MAKING THE PROPER CONNECTIONS,
BE SURE TO CHECK FOR LEAKS. APPLY A 50/50 MIXTURE OF DISH SOAP AND WATER
MIXTURE TO ALL CONNECTIONS. BUBBLES FORMING ARE EVIDENCE OF A LEAK. BE SURE
TO CORRECT ALL LEAKS AT ONCE.
1. Provide propane supply system as outline above.
2. Connect POL fitting on hose/regulator assembly to propane
tank(s) by turning the fitting COUNTERCLOCKWISE into the
threads on the valve on top of the tank. Finish by tightening
firmly, using 7/8" wrench.
Important: To protect the regulator from weather damage,
tighten the fitting with the black adjustment knob pointing
down.
3. Connect female end of hose to the inlet connector of the
heater, and tighten firmly with a wrench.
Important: Use extra piping or hose if necessary to con-
nect the heater to the gas supply, but always use the
regulator supplied with the heater.
4. Open supply valve on propane tank(s) SLOWLY.
Note: If this valve is not opened slowly, the excess flow tank will
interrupt the gas flow. If this happens, close the supply valve and
reopen slowly.
5. Adjust the regulator to between 7 and 18 PSIG.
WARNING: DO NOT ADJUST THE REGULATOR ABOVE
18 PSIG OR BELOW 7 PSIG, OR THE HEATER MAY
NOT OPERATE PROPERLY.
6. Check all connections for leaks.
WARNING: NEVER USE AN OPEN FLAME TO CHECK FOR LEAKS. APPLY A 50/50 SOLUTION
OF LIQUID DISH SOAP AND WATER TO CHECK ALL CONNECTIONS. CORRECT ALL LEAKS
IMMEDIATELY.
7. Close propane supply valve.
VENTILATION
WARNING: ALWAYS FOLLOW THE MINIMUM FRESH AIR VENTILATION REQUIREMENTS. IF
THESE GUIDELINES ARE NOT FOLLOWED, CARBON MONOXIDE POISONING CAN OCCUR.
ALWAYS PROVIDE PROPER AMOUNTS OF FRESH AIR BEFORE OPERATING THIS HEATER.
Provide at least three square feet of fresh, outside air from each 100,000 BTU/Hr of rating. This heater re-
quires a fresh air opening of at least 11.25 square feet. Provide extra fresh air if more heaters are being used.
WARNING: NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A
POWER SOURCE
12
INSTALLATION
Supply Valve
Propane/LP
Tank
POL Fitting
Hose
Regulator
Adjustment Knob
(Pointing Down)
Hose
Inlet Connector
Propane Portable Heater Manual