Techni-
Alarm
Priori-
cal pa-
condi-
ty
rameter
tion
ICT
Average
High
measure-
ICT out-
ment
side
range
meas-
urement
range
NOTE
The DEACTIVATED ALARM status does not disable the
signals (visual and audible) of the technical alarms.
Disconnection of the Catheter disables the signals (vis-
ual and audible) of the technical alarms.
Operator position in terms of alarm readability: in front of the
®
Pressio
2 ICP Monitor screen.
Alarm condition delay
Physio-
ICP
ICT
Fault in
logical
the
parame-
Cathe-
ter
ter
pres-
sure
sensor
Average
8 s
1 s
<1 s
alarm con-
dition de-
lay
Statistical
8 s
1 s
<1 s
condition
statistical
delay
Average
0 s
0 s
<1 s
alarm gen-
eration
delay
18. Electromagnetic Compatibility
WARNING
Use of the Monitor adjacent to or stacked with other
equipment should be avoided because it could result in
improper operation. If such use is necessary, the Moni-
tor and the other equipment should be observed to ver-
ify that they are operating normally.
Page 32 of 174
Re-
Sound indica-
Visual indi-
sponse
tors
cators
time
Prompt
Three-pulse
The mes-
sound, pause
sage E005
for 300 ms,
ALARM
two-pulse
displays.
sound, pause
The display
for 500 ms,
area flash-
three-pulse
es red at a
sound, pause
frequency
for 300 ms,
of 2 Hz.
two-pulse
sound
The pulses are
separated by
100 ms
Sequence rep-
etition interval:
2.5 s
The pulse vol-
ume is 55 dB
Fault
Cathe-
Aver-
in the
ter
age
Cathe-
cali-
ICP
ter
bra-
out-
tem-
tion
side
pera-
fault
meas-
ture
ure-
sensor
ment
range
<1 s
<1 min <1 s
<1 s
<1 min <1 s
<1 s
<1 min <1 s
Alarm condition delay
Physio-
logical
parame-
ter
Statistical
alarm gen-
eration
delay
Sum of
the
ALARM
SIGNAL
GENERA-
TION DE-
LAY and
average of
ALARM
CONDI-
TION DE-
LAY
Sum of
the
ALARM
SIGNAL
GENERA-
TION DE-
LAY and
distribu-
tion statis-
Aver-
tics of the
age
ALARM
ICT
CONDI-
out-
TION DE-
side
LAY
meas-
ure-
ment
Behavior of alarms following a power cut or powering off
range
<1 s
Power cut
≤ 30 s
Power cut
<1 s
> 30 s
Power cut
> 30 s
<1 s
Monitor
powered off
WARNING
Use of accessories, transducers and cables other than
those specified or provided by Sophysa could result in
increased electromagnetic emissions or decreased
electromagnetic immunity of this equipment and result
in improper operation.
ICP
ICT
Fault in
Fault
the
in the
Cathe-
Cathe-
ter
ter
pres-
tem-
sure
pera-
sensor
ture
sensor
0 s
0 s
<1 s
<1 s
8 s
1 s
<1 s
<1 s
8 s
1 s
<1 s
<1 s
Battery status
Alarm status
OK
Conserved
OK
Conserved
Flat
Activated (by
default)
OK or flat
Activated (by
default)
Cathe-
Aver-
Aver-
ter
age
age
cali-
ICP
ICT
bra-
out-
out-
tion
side
side
fault
meas-
meas-
ure-
ure-
ment
ment
range
range
<1 min <1 s
<1 s
<1 min <1 s
<1 s
<1 min <1 s
<1 s
Alarm thresholds
Conserved
Conserved
Conserved
Conserved