6.5 Steel ring scraping and tire wearing on tire dismounting head:
- Untight hexagonal prism pin lock
- Loose mounting head screws or wrong orientation
- Large clearance between the hexagonal prism and the hexagon sleeve
Maintenance method:
- Adjustment of loose mounting head screws: Pre-tighten (not too tight) the screws first, and then tighten the screws. When tightening the
screws, install a medium-sized tire so that the trolley wheel of mounting head rests on the steel ring, rotate the direction of mounting
head to match it with the radian of steel ring, tighten again, and finally screw down.
- If the hexagonal prism is pulled manually and the swing is relatively large, replace the rocker arm.
6.6 The claw does not open or close properly:
check whether there is air leakage, check whether the five-way valve core jumps out of the pedal fork. If the above is normal, check
whether there is gas blow-by in the rotary distribution valve. When the pedal is not stepped or fully stepped, only one of the air pipes
connecting the rotary valve to the small cylinder is ventilated. In any case, the explanation for the phenomenon that the two gas pipes are
not ventilated at the same time is that there is gas blow-by from the rotary distribution valve. If there is no problem in the above parts,
check the mechanical part. Whether the claw seat is deformed or jammed, whether the square rotary table is jammed, whether the square
rotary table is jammed, and whether the pin of the square rotary table falls off.
6.7 Common troubleshooting methods
Fault phenomenon
Steel ring scraping/tire
wearing on mounting head
Failure in clamping the rim
with claw
Large cylinder inability
AE103H/AE1023H-3
Fault causes
Displacement of mounting head caused by loose column
Displacement of mounting head caused by loose rocker
arm/slide arm
Displacement of mounting head caused by large
hexagon rod clearance
Loose mounting head
Falling off of plastic spacer on mounting head
Too small clearance between mounting head and rim
Air leakage/gas blow-by of clamping cylinder
Air leakage/gas blow-by of rotary distribution valve
Wrong position/air leakage/gas blow-by of five-way
valve
Low air pressure of oil atomizer
Decentraction/damage of four claws
Large cylinder air leakage/gas blow-by
Wrong position/air leakage/gas blow-by of five-way
valve
Low air pressure of oil atomizer
Low cylinder intake
中文
EN
DE
RU
KO
Troubleshooting methods
Locking column
Adjust rocker arm/slide arm clearance
Adjust hexagon rod clearance
Lock the mounting head
Mount the plastic spacer
Adjust the clearance between mounting
head and rim 2-4 mm
Check connection of gas pipe/replace
sealing ring
Check connection of gas pipe/replace
sealing ring
Adjust the position of five-way valve/
replace O-ring
Adjust the oil atomizer pressure/check the
gas source pressure
Adjust the claw distance the eccentric
bearing/ replace the claw
Check connection of gas pipe/replace
sealing ring
Adjust the position of five-way valve/
replace O-ring
Adjust the oil atomizer pressure/check the
gas source pressure
Adjust limit screws on five-way valve pedal