Do not remove or modify any component of this machine (these operations may
only be carried out by technical assistance personnel).
When the machine is disconnected from the pneumatic power supply, the pneumatic
actuators can remain pressurized.
Before carrying out any regular maintenance operation or topping up with lubricant,
disconnect the machine from the compressed air supply line.
The manufacturer declines all responsibility for claims resulting from the use of
non-original spare parts or accessories.
- Regularly clean the machine from dirt
- Keep all guides clean and lubricated (vertical axis, horizontal axis, jaw guides)
- The purpose of the regulator filter and lubricator (FRL) unit is to filter the air, adjust the
pressure and lubricate it.
The "FRL" unit supports a maximum input pressure of 16 bar and has an adjustment
range between 0.5 to 10bar, this adjustment can be modified by pulling the handle to
the extracted position and turning it. At the end of the adjustment, return the handle to
the locked position pushing it downwards (fig.42a).
The lubricant flow rate adjustment is carried out by turning the screw on the element "L",
(fig.42b); normally this unit is pre-calibrated to a pressure of 10Bar, with SAE20 viscosity
lubricant in order to make a drop of lubricant come out, which can be seen from the
specific cover, every 4 times the bead breaker is operated.
Periodically check the lubricant level through the specific windows and top up as shown
in fig.42c. Top up only with non-detergent SAE20 oil equal to 50cc.
The filter regulator "FR" has an automatic condensation drain system, therefore in condi-
tions of normal use special maintenance is not required. The condensate may however
be drained manually at any time (fig.42d). Normally the cups do not need to be removed,
but check if this is necessary for maintenance operations after a long period of use. If a
manual operation is not sufficient, use the specific key provided (fig.42e).
Clean with a dry cloth. Avoid contact with solvents.