How To Wire Your Ceiling Fan - Emerson ASHLAND CF717BS01 El Manual Del Propietario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.
WARNING
!
To avoid possible electrical shock, be sure electricity is
turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is grounded,
contact a licensed electrician for advice, as it must be
grounded for safe operation.
WARNING
!
Turning off wall switch is not sufficient. To avoid possible
electrical shock, be sure electricity is turned off at the
main fuse box before wiring. All wiring must be in
accordance with National and Local codes and the ceiling
fan must be properly grounded as a precaution against
possible electrical shock.
8.1
Connect the green grounding lead from the hanger ball
and the green grounding lead from the hanger bracket to
the grounding conductor of supply (this may be a bare
wire or wire with green colored insulation)
(Figure 16). Securely connect wires using wire connectors
supplied.
8.2
Securely connect the fan motor white wire to the supply
white (neutral) wire using wire connector supplied
(Figure 17).
Securely connect the fan motor black wire and blue wire to
the supply black (hot) wire using wire connector supplied
(Figure 17).
After connections have been made, turn leads upward and
carefully push leads into the outlet box, with the white and
green leads on one side of the outlet box and the black
and blue leads on the other side of the outlet box.
WARNING
!
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.

8. How to Wire Your Ceiling Fan

Figure 16
NOTE: When wiring the ceiling fan for close-to-the-
ceiling mounting, there will be no green grounding
lead from the hanger ball.
!
This product is designed to use only those parts supplied
with this product and/or any accessories designated
specifically for use with this product by Emerson Electric
Co. Substitution of parts or accessories not designated
for use with this product by Emerson Electric Co. could
result in personal injury or property damage.
WIRE CONNECTOR
BLACK
SUPPLY (HOT)
BLUE
FAN WIRE
BLACK
FAN WIRE
WHITE SUPPLY
NEUTRAL)
WHITE FAN WIRE
Figure 17
12
SUPPLY
GROUND WIRE
GREEN GROUND
WIRE FROM
HANGER BRACKET
GREEN GROUND
WIRE FROM
HANGER BALL
WARNING
ETL Model No.: CF717-1

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ashland cf717orb01Ashland cf717sw01

Tabla de contenido