8. Programming the Receiver Operating Frequency

& High Speed Conditioning of Fan Control
-- Important - Read This Section Carefully and Follow
the High Speed Conditioning Instructions Closely --
IMPORTANT: Ceiling fan blades MUST be installed
before high speed conditioning can begin.
NOTE: If using a 3-way Switch Installation, ensure
that both Wall Controls are using the same Switch
Code.
PROGRAMMING THE RECEIVER
OPERATING FREQUENCY
8.1
Flip the Wall Control ON/OFF Switch (
"OFF" ( O ) position .
Restore Electricity to the Ceiling Fan Branch Circuit at
the Circuit Breaker Panel or Main Fuse Box .
Flip the Wall Control ON/OFF Switch to "ON" (
position .
Within 1 Minute of flipping the Switch to "ON", push
and hold the FAN OFF Button (
to set the Code in the Receiver . The ceiling fan lights
(if installed) will blink to indicate the Wall Control Code
has been paired with the Receiver .
IMPORTANT: Immediately after successful pairing,
the ceiling fan will automatically begin high speed
conditioning of the motor. During conditioning, the
electronic motor control software is calculating
speeds for the 2nd through 5th speed settings
based on the blades that were installed on the fan.
The Fan will run for approximately 1 Minute in the
upward direction then Reverse direction to down flow
and run an additional 1 Minute . When conditioning is
complete, the Fan will come to complete stop .
IMPORTANT: Do not interrupt the conditioning until
the fan comes to a complete stop in approximately
2 minutes. All functions of the control will be
rejected during conditioning.
High speed conditioning is now complete .
8.2
) to the
If programming is unsuccessful, retry the Step 8 .1
instructions after cycling the Wall Control ON/OFF
Switch to restart the 1 minute programming time period .
)
8.3
If still unsuccessful, shut OFF the Electricity at the Main
) for 3 to 5 seconds
Fuse Box or Circuit Breaker Panel and change the
Wall Control frequency (Page 17) . After changing the
Frequency settings, repeat Step 8 .1 within one minute
of restoring the Electricity .