Nogueira FTN-1900 Manual De Instrucciones página 237

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6.4- How to change the rotor knives
The entire set of knives must be replaced
when there is worn or damaged, making it
impossible to sharpen and adjust with the
counter knife.
ATTENTION!
Turn off the tractor and remove
the ignition key before starting
the following procedure.
IMPORTANT!
To keep the rotor balance, always
replace all knives. The unbalance will
cause vibrations and machine damage.
Fully lower the outlet chute;
1.
Loosen the jam nut (A);
2.
Turn the tensioner (B) to loosen it;
3.
Remove the pins (C);
4.
Carefully lower the tensioner (B);
5.
Ask for help to hold the chute and remove
6.
the 2 bolts (D);
Remove the lifting tube (E) with the outlet
7.
chute;
Remove the two covers (F) from the
8.
sharpeners;
Remove the 12 bolts (G) that secure the
9.
two covers to the machine;
A
D
B
Instructions Manual
6. Maintenance
C
E
G
G
D
H
97

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido