Standard Safety Edges Configuration; Radio Receiver Plug-In; Display Operation Modes; Test Mode - Roger Technology H70/104AC Instrucciones Y Advertencias Para El Instalador

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 57
IF THE PHOTOCELLS 1 IS NOT INSTALLED
50 00
51 00
Set
and
IF THE PHOTOCELLS 2 IS NOT INSTALLED
53 00
54 00
Set
and
Or electrically bridge their terminals with the COM
terminal block.
4.4

Standard safety edges configuration

Inputs COS1 and COS2 are disabled as factory
standard.
To enable and configure them please refer to the
parameters in extended mode
5

Radio receiver plug-in

The receiver (see figure 1) provides two functions
for radio remote control that are assigned in the
following way as a production standard:
PR1 step-by-step control (can be changed by
adjusting parameter
PR2 command pedestrian opening control (can
be changed by adjusting parameter
extended mode)
6

Display operation modes

The screen can display the following information,
depending on the operating mode the control unit
is in:
• COMMANDS AND SAFETY PROTECTIONS STATUS
MODE: the status of the control inputs is shown
by two digits on the left, in the two digits on
the right the status of the safety protections is
shown by two digits on the right. As soon as the
display control unit is powered in this mode. In
any other condition just press the UP or DOWN
key several times until it displays the status of
the inputs. The status of the inputs is found after
the last parameter and before the first parameter.
See section 6.1 for a full description.
• PARAMETERS MODE: the two digits on the left
will display the name of the parameter, the two
digits on the right display its numerical value.
See section 6.2 for a full description.
• MODALITA' STANDBY: makes the LED "POWER" flash
which indicates the presence of the power supply
voltage (decimal point of the furthest left digit).
See section 6.3 for a full description
• TEST MODE: the two digits on the left display
73
74
and
76
of extended mode)
77
the name of the active command (for 5 seconds,
then it goes off), the two figures on the right
display, flashing, display the number of the safety
protection terminal block possibly in a state of
alarm. To exit this mode press the TEST button.
See section 6.4 for a full description.
6.1

Commands and safety protections

The inputs are shown on the display in the following
way:
STATUS CONTROLS
AP
.
PP
CH
POWER
ALWAYS ON
If the input is closed the corresponding segment
of
comes on. The segments corresponding to the
controls will normally be turned off (normally
open contacts), will be turned on upon receipt of
a command. The segments corresponding to the
safety protections installed must be turned on
(normally closed contacts); if they are turned off it
means that they are in a state of alarm.
SAFETY PROTECTIONS DISABLED BY PARAMETER:
the corresponding LED segment flashes.
NO SAFETY PROTECTIONS: the segment never
appears
6.2

Parameters mode

UP
DOWN
UP
next parameter
DOWN
previous parameter
+
increases the parameter value by 1
-
decreases the parameter value by 1
PROG
programming the stroke (see par. 7)
TEST
enables test mode (see par. 6.4)
STATUS SAFETY PROTECTIONS
PED
FT1
COS1
ORO
COS2
ENC
SB
FT = Photocells
COS = safety edge
SB = unlock
PARAMETER
VALUE
PROG
TEST
FT2
STOP
+
-
23

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

H70/105ac

Tabla de contenido