Types Of Installation - GIERRE BAKETEK 0564E Serie Instrucciones Para La Instalación, El Uso Y El Mantenimiento

Hornos a convección-humidificación para uso profesional
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

GB

Types of installation

The oven must only be installed in adequately ventilated places observing current national and local
regulations, and preferably under an extraction hood.
The type of the installation is indicated on the oven's label.
Installers will appraise onsite which fume extraction system is the most suitable for the room.
A-type installation :
Basing on A-type installation, ovens can be simply installed in a ventilated room observing current
national and local regulations. It is always advisable to sent them under an extraction hood to let
combustion steam and gases to escape.
B-type installation :
Basing on B-type installation, ovens must be connected to an escape pipe to provide combustion gases a
natural escape. Connect a pipe adequate in diameter
In case of an installation under a hood, the connection chimney should be raised up to an adequate height
in order to set the distance between the end of the chimney and the hood filter between 180 mm e 250
mm.
In this type of installation an appropriate gas interception valve must be used to fit the extractor hood.
Z
Type of gas
Chimney diameter
Chimney length
(CO) Carbon monoxide measured
M
(CO ) Carbon dioxide measured
2 M
Combustion fumes pressure
Combustion fumes temperature
Mass (flow) exhaust fumes
TYPE B11
PARAMETERS TO THE CHIMNEY
Z
(not included) in the sleeve of the draught switch.
BAKETEK 1064G...
(16 kW)
G30
G31
Ø 120 mm
Ø 120 mm
Ø 120 mm
1 meter
1 meter
1 p.p.m.
1 p.p.m.
3,16 %
3,08 %
-2,9 Pa
-2,8 Pa
188,5° C
190,3° C
22,06 g/s
22,01 g/s
42
G20
G25
Ø 120 mm
1 meter
1 meter
8 p.p.m.
2 p.p.m.
2,91 %
2,85 %
-3,0 Pa
-2,9 Pa
191,2° C
188,5° C
21,36 g/s
21,41 g/s