GB
WARNING!
If the power cable is damaged, it must be replaced by the manufacturer or by its
technical assistance service, or in any case by a person having a similar qualification, so
as to prevent any risk.
Gas connection
Make sure there are no leaks in the linking point and check the compatibility of the device to the gas
supply. If necessary, adapt the device to the type of gas supplied only after reading carefully the
"ADAPTING TO DIFFERENT TYPES OF GAS" paragraph
The gas connection must feature a quick closing interception valve according to current rules.
After the connection, it is recommended a leakage test using a leak-detecting spray, which must be
against corrosion. The gas must agree with the data of the rating plate. (
Before starting installation
Please, check the type of gas the appliance can work with, before using the
appliance.
Adapting to different types of gas
To adapt the appliance to other types of gas it is necessary to refer to a qualified installer. A special plastic
bag which comes with the appliance, contains the nozzle and the technical plate suitable for the
replacement.
• Replacement of nozzles and adjustment of air burners:
•remove the protection below the oven to get easier access to the components of the air burner;
•loosen the screw
•bring the bush
(B-
screw in and lock the screw
• Adjustment of the
•To access the valve it is necessary to remove the left side of the oven;
•The use of a manometer at a minimum setting of 0,2 mbar is requested.
1
2
3
4
5
A
procedures consult your gas suppliers.
Fig.
(V-
5),
unscrew the nozzle
Fig.
5)
to distance
Fig.
(V-
5)
gas
valve
:
Fig. 4
.
Fig.
(A-
H
as showed;
to lock the bush and seal with red enamel.
44
see paragraph 1.3
5)
and replace it as shown on the table ;
).
T