SMA Solar Technology AG
• Insert the communication assembly into the left-
hand retainer.
• Push the right-hand retainer outwards and
insert the communication assembly into the
right-hand retainer.
• Push the communication assembly into both
retainers until it snaps into place.
2. Fold the communication assembly downwards.
Make sure that the ribbon cable is not clamped by
the communication assembly or when closing the
lower enclosure lid.
3. Tighten the screw of the communication assembly.
4. Insert the plugs of each ribbon cable into the
corresponding pin connector. Press the lock hooks
on the pin connector apart.
☑ After inserting the plug, the lock hooks close.
5. Recommission the inverter (see Section 7, page 17).
7
Recommissioning the Inverter
If you have disconnected the inverter from all voltage sources and want to recommission it, proceed
as follows.
Requirements:
☐ The inverter must be correctly mounted.
☐ The DC connectors must be correctly assembled.
☐ The AC cable must be connected correctly.
☐ If you need to update to firmware version ≥ 3.00.00.R, the existing SD memory card must be
inserted in the slot of the new communication assembly.
Replacement Manual
7 Recommissioning the Inverter
SB5GCOM-STPTL30-RM-xx-10
17