Storage And Transport; Scheduled Maintenance Table - Spasciani RC Manual Del Usuario

Ocultar thumbs Ver también para RC:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

It is allowed to exceed filling pressure by not more than 10% since when the cylinder cools down, the pressure will 
become the nominal working pressure. For recharging be sure that: 
 Air meets the requirements of EN 12021  
 The date of last pressure test is engraved onto the cylinder  
Cylinder valve has to be kept shut whilst being sent to refilling to avoid moisture from entering it. Cylinder shall be 
protected from shocks during transport and storage. Do not carry cylinders by the hand wheel valve. 
8.2 Cleaning and disinfecting 
After each use is necessary to clean the dirty parts. This should be done with warm soapy water. The rinse should be 
done with fresh running water. 
N.B.:  If  chemical  products  are  used,  follow  the  advice  for  concentration.  Avoid  the  use  of  organic  solvents  that  can 
damage rubber and plastic 
9.
TESTING 
N.B.: The following tests shall in any case be performed after cleaning or repairs. 
The demand valve membrane as well as all rubber parts shall be replaced (by trained and authorized personnel) if they 
show signs of alteration or ageing (sticky, hardened, creased etc.). All fittings  shall be free  from evident alteration. 
SPASCIANI S.p.A. supply on request the equipment for proper testing. 
9.1 Demand valve tightness at +7 mbar 
- Connect cylinder to pressure reducer. Cylinder shall be kept shut 
- Connect the demand valve to the medium pressure line 
- Release button (17) by pushing on rubber button (4) 
- Connect the demand valve to the testing instrument 
- Pump some air into the demand valve to reach a pressure of some +7 mbar. Pressure drop shall not exceed 1 mbar 
within one minute. 
9.2 Positive pressure of the demand valve 
- Open cylinder valve 
- Connect demand valve to testing equipment 
- Release button (17) by pushing on rubber button (4) 
- The control pressure gauge shall read 3.2 to 3.9 mbar. 
9.3 Pressure in the cylinder 
See par. 6.4. 
9.4 Tightness of the high pressure section 
See par. 6.5. 
9.5 Warning device 
See par. 6.6. 
10.
STORAGE AND TRANSPORT 
It is advisable to store the respirators herein described in suitable areas at normal room temperature, away from sun 
light, humidity and corrosive chemicals. The pictograms on the label indicate the optimal conditions of storage. 
For the carriage of cylinders, follow the instructions in the section. 8.1. For the transport of other components, it is not 
required a special care, however it is recommended to use the original packaging of mask and regulator and follow the 
directions provided for storage. 
11.
SCHEDULED MAINTENANCE TABLE 
The following table shows the maintenance schedule: 
Part 
Complete airline 
Complete airline 
Demand valve 
Demand valve 
Demand valve 
Demand valve 
High pressure connector 
High pressure connector gasket 
Reducer 
Cylinder 
Full face mask 
1: Before allowing the use 
4: Every six months 
7: Every six years 
a) After use in corrosive areas or in extreme ambient conditions 
b) In accordance to national regulations 
c)  WARNING:  Every  time  the  valve  is  disassembled  from  the  cylinder  for  maintenance  and/or  testing,  the  valve  shall  be 
   
 
 
 
 
Activity
Cleaning
Function, tightness
Cleaning
Disinfecting
Membrane check 
Membrane replacement
Thread test
Replacement
Revision
c
Test
 
See mask instruction
2: Before use
5: Annually
 
 
 
 
 
1
2
3
X
X
X
X
a
X
3: After use
6: Every three years 
 
 
 
 
                Pag. 16 / 36 
6
7
 
 
 
 
 
 
 
 
 
 
X
 
 
X
 
 
 
X
b
 
 
X
 
 

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rl

Tabla de contenido