Trimmer A
Trimmer B
Couple regulation
-
Trimmer A
Trimmer A (couple reg.): it adjusts the intervention time of the electronic power limiter. By turning it
counterclockwise the circuit is more sensitive (a light effort is enough to stop the movement); on the
contrary, by turning it clockwise the circuit becomes less sensitive and a great effort is necessary to
stop the motor; in this condition the motor can absorb up to 24A of peak (576W) at maximum speed.
Trimmer B (Cycle sp.): it adjusts the movement speed of the automation during the working cycle. By
turning it counterclockwise the speed decreases.
Trimmer C (Brake Sp.): it has the same function of the trimmer B as far as the brake cycle is concerned.
Trimmer D (Pause time): it adjusts the length of the pause between the aperture and the closing when
the function of automatic closing is inserted. By turning counterclockwise the time decreases (min. 2 s);
by turning it clockwise the time increases (max. 100 s).
Dip fix (Aut. Clos.): Open, it activates the function of automatic closing.
On the basis:
Condominium function: it is obtained by linking the clamps 4 (aperture push-button) and 10 (step-by-
step) together; in this way it is not possible to stop the aperture and invert the movement by means of
the step-by-step or radio-control.
12
Settings and selections
Trimmer C
Trimmer D
Cycle speed
regulation
+
-
+
Trimmer B
Central unit board
Braking speed
regulation
Pause time
regulation
-
+
-
Trimmer C
Trimmer D
Connector
Automatic closing
Open
Closed
Dip-fix
+