13) Push the button Aperture. The automation must move towards aperture; if it moves towards closing
push the stop button, disconnect the 230Vac and the batteries and invert the motor connections.
Connect the 230Vac and the batteries again and push the aperture push-button.
14) Do the adjustment of the working speed by means of the trimmer B (cycle speed) and wait for the
arrivel to the stop.
Regulate the intervention of the braking circuit, by placing the cams on the stops and by regulating
the trimmer C (braking speed) to obtain an easy stop.
15) Push the button Closing and adjust the power through the trimmer A (reg. couple) so that, with a
light effort, the movement can be stopped.
Remember that the setting of the couple adjustment trimmer depends on the adjustment done on
the cycle speed trimmer and on the brake speed trimmer; then, after any change of the cycle or
brake speeds the couple adjustement trimmer should be adjusted.
See the diagram "Adjustments and selections".
16) Check the working of the security devices, remembering that:
by pushing the stop in any condition, the unit stops and waits for an order;
the intervention of the photo-devices in closing phase causes the inversion of the movement at
once, while in aperture there is no intervention.
17) If you want to exclude the intervention of the step-by-step in aperture and in pause after automatic
closing (condominium function) connect the clamps n
by-step) together.
N.B.: Any time the manoeuvres cause confusion, disconnect the batteries and the 230Vac for a few
seconds, and then give tension again and proceed.
N.B.: Without 230Vac mains, and with completely decharged batteries it is possible to make from 10 to
30 complete cycles of manoeuvre, according to the weight of the automation.
N.B.: Avoid the extreme adjustments of speed and power.
N.B.: The minimun section of the motor wires must be:
1.5mm
2
for lenghts to 1 m.
2.5mm
2
for lenghts to 3 m.
4.0mm
2
for lenghts to 6 m.
Before any intervention on the unit disconnect the 230Vac line and the batteries.
°