Step
Display
Description
External temperature sensor calibration:
(If WtS or OtS has been selected at Step 20 . )
Display shows
21
read by the external temperature sensor (if connected on the selected input) .
If the sensor is not connected or short circuited, the display shows Eror .
You can adjust the calibration of the external sensor by comparison with a
known thermometer .
Window temperature sensor compensation factor:
(If WtS has been selected at Step 20 . )
For window temperature sensor only, see Temperature Compensation
section for Outdoor Temperature Sensor operation.
22
Display shows
compensation factor .
You can adjust the compensation factor to avoid condensation on the window .
The lower the compensation factor, the lower the maximum humidity set point
can be .
24 English
extern temper sensor offset
window temper sensor compens
Values
Range: -30 to 90°C
and the temperature
Increment: 0 . 1 °C [0 . 2 °F]
Range: 25 to 90
Increment: 5
Default setting: 80
and the value of the
[-22 to 194°F]
(max . offset ± 5°C)