HOSE CONNECTIONS AND STEAM MANIFOLD INSTALLATION
Connect the steam hose (provided with the Steam Humidifier) to the
Fan Pack Steam Manifold and use hose clamp (provided with the Steam
Humidifier) to secure . Then install the steam manifold into the Fan Pack
cabinet by feeding the steam hose back into the wall cavity, and secure
the manifold with the two serrated nuts (included) . See FIGURE 9 . A
45° stainless steel elbow is provided for installations with the Steam
Humidifier mounted on the wall behind the Fan Pack . See FIGURE 5 .
If more than 6 feet is required, use insulated hard pipe as shown in
FIGURE 6 . See the Steam Humidifier manual for the effect on capacity .
GRILLE INSTALLATION
Use the four 5/8" screws to attach the Fan Pack grille to the fan housing
and drywall . See FIGURE 10 . If painting the grille is desired, see a
painting professional for acceptable paint products for high temperature
(212°F), high humidity environments and polycarbonate .
FIGURE 10 – GRILLE INSTALLATION
8 English
FIGURE 9 – HOSE CONNECTIONS
90-2212
ELECTRICAL TERMINALS
TO STEAM HUMIDIFIER
90-2197