Control Panel - KBS TKU 821 EIS Traducción Del Manual Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 28
Translation of the original instructions

Control Panel

KEYPAD and ASSOCIATED FUNCTIONS
The keypad is blocked by keeping
for a few seconds: "Loc" will appear on the display.
Pressing them once again will unblock the keypad: "UnL" will appear
on the display.
ON/STAND BY
Press this button for a few seconds to switch the appliance into
status ON or STAND BY.
MANUAL DEFROSTING
Press this button for a few seconds to activate manual defrosting, if
the temperature of the evaporator allows it and provided that the
Overcooling function is not activated.
If the defrosting time interval elapses while Overcooling is in
progress, the former will be activated upon conclusion of the latter.
CHAMBER LIGHT / CONTINUOUS COLD (IF
PRESENT)
Press the auxiliary button to switch the chamber light on and off
manually (only glass door version)
Press it for 4 sec. to prepare the appliance for its intense use during
the refrigerator production and load phase (if present)..
The latest time set appears on the display and it can be modified
pressing the UP and DOWN keys (with adjustment every 30 minutes).
Hold the
key down to start the cycle; a defrosting cycle is started (if
required); then, the compressor will run continuously for the time set,
without any other defrosting cycles.
The display shows alternatively the remaining time and cell temperature.
During this phase, press the key again
stop the cycle resetting the value to "00:00" and then hold the key
down again .
DOWN button
This scrolls the menu items and decreases the values.
UP button
This scrolls the menu items and increases the values.
When pressed for a few seconds, the low RH% function ("rhL"
appears on the display) or the high RH% function ("rhH" appears on
the display) is activated for 10 seconds.
If the function is not available and the button is pressed, "----" will
appear on the display.
SET POINT
This provides access to the set point edit function.
STOPPING THE BUZZER (IF PRESENT)
Briefly press any button.
SETTING THE SET POINT
Press the SET ( ) button: the compressor LED will flash.
Press the UP ( ) or DOWN ( ) button within 15 seconds.
and
pressed simultaneously
to modify the set time or
Press the SET ( ) button or do not operate for the compressor LED to
go off, after which the instrument will exit from the procedure.
DO NOT PERFORM ANY MAINTAINANCE WHEN THE
APPLIANCE IS IN ON OR STAND BY
DISCONNECT FROM ELECTRICAL POWER SUPPLY NET.
INDICATORS
LED
MEANING
ON: The compressor is on
FLASHING: The working Set Point is being changed
Compressor protection in progress
ON: Defrosting in progress
FLASHING
Defrosting requested but compressor protection is in progress
Dripping in progress; Heating coolant in progress
ON The evaporator fan is on
FLASHING The evaporator fan is being stopped
ON : Chamber light switched on manually
FLASHING Chamber light switched on automatically
ON
The anti-steaming up resistors will be switched on
Auxiliary output switched on manually
Alarm output activated
The door resistors will be switched on
FLASHING : Auxiliary output switched on remotely
ON Overcooling in progress
ON Alarm or error in progress
ON: Not all the information regarding the HACCP alarms has
been displayed
FLASHING : At least one new alarm has been saved
OFF : All the information regarding the alarms has been displayed
List of the HACCP alarms has been deleted
ON Energy Saving in progress
ON Compressor maintenance required
ON The temperature measurement unit will be degrees Celsius
ON The temperature measurement unit will be degrees Fahrenheit
ON: The instrument is on stand-by
INDICATIONS
CODE MEANING
rhL
Low RH% function selected
rhH
High RH% function selected
Loc
The keypad is blocked; The working Set Point is blocked
- - - -
Requested function is not available
ENGLISH 5