Troubleshooting

NOTICE: This pump has no serviceable parts inside the
case. Opening the case will ruin the pump. For obstruc-
tions or blockages of the impeller, replace the pump.
SYMPTOM
POSSIBLE CAUSE(S)
Pump won't
Blown fuse or circuit breaker has tripped
start or run
Low line voltage
Defective motor
Pump operates but
Low line voltage
delivers little or no
water
Something caught in impeller
Worn or defective parts
Check valve installed without
vent hole
Intermittent running
Thermal overload has tripped
or pump stopped
automatically
For parts or assistance, call Simer Customer Service at
Hazardous voltage; can shock, burn or kill.
Unplug the pump before attempting to clean or work on
the pump.
CORRECTIVE ACTION
If blown, replace with fuse of proper size or reset circuit breaker
If voltage under recommended minimum, check size of wiring from main
switch on property. If OK, contact power company or hydro authority
Replace pump
If voltage under recommended minimum, check size of wiring from main
switch on property. If OK, contact power company or hydro authority.
Replace pump
Replace pump
Drill a 1/16" - 1/8" (1.6mm - 3.2mm) dia. hole between pump discharge
& check valve
Protect the installation from the sun
Pump cooler water
Pump has run dry; add water