Altitude during measuring: 2000 m maximum
-
Overvoltage category/ Location category: IEC 664/ IEC 1010 600 V
Category II,
-
Pollution degree: 2,
-
Protection Class: IP 30 (DIN VDE 0470-1 IEC/ EN 60529)
IP 30 means: Protection against access to dangerous parts and protection
against solid impurities of a diameter > 2.5 mm, (3 - first index). No
protection against water, (0 - second index).
-
Working temperature and relative humidity:
for working temperatures between 0 °C and 50 °C: relative humidity smaller
than 80%
-
Storage temperature: the BENNING CM 3 can be stored at temperatures
between - 20 °C and + 60 °C. The battery should be removed when meter
is in storage.
7.

electrical specifications

Note: measurement accuracy is given as the sum of
-
a relative percentage of the reading and
-
the number of least significant digits
This accuracy is valid for a temperature of 23 °C, with a relative humidity smaller
than 75 %.
7.1 Direct current ranges
Accuracy is ± (% of reading + number of digits) at a temperature of 23 °C
± 5 °C.
Measuring range
200 A
600 A
7.2 Alternating current ranges
Accuracy is ± (% of reading + number of digits) at a temperature of 23 °C
± 5 °C.
Measuring range
200 A
600 A
8.
Measuring with BeNNING CM 3

8.1 Measurement preparation

The BENNING CM 3 must be used and stored only at the indicated storage and
working temperatures, avoid exposure to continuous sunlight.
-
If the BENNING CM 3 is used near strong noise generating sources, the
display may become unstable and measurement errors may arise.
To avoid electrical shock, observe the maximum rated voltage
to earth ground!
The maximum rated voltage that should be applied between the BENNING CM 3
and earth ground is 600 V.

8.2 Current measurement

-
Use switch  to select the current type and switch  to select the range
on BENNING CM 3.
-
Before DC current measurements turn adjusting knob  on the
CM 3 to obtain reading of "0" on the display .
-
Press the trigger button  to open the clamp jaws and clamp one single
lead conductor.
-
Read the measurement value from the digital display .
see Figure 2:
see Figure 3:
9.
Maintenance
Remove test leads and turn the power off before opening the
BeNNING CM 3! Dangerous voltage!
06/ 2008
Resolution
0,1 A
1 A
Resolution
0,1 A
1 A
DC current measurement
AC current measurement
BENNING CM 3
Measurement accuracy
0 - 20 A ± (1,9 % of reading + 5 digits)
20 - 200 A ± (1,9 % of reading + 3 digits)
200 - 600 A ± (1,9 % of reading + 3 digits)
Measurement accuracy
0 - 20 A ± (1,9 % of reading + 7 digits)
20 - 200 A ± (1,9 % of reading + 5 digits)
for frequency range 40 - 400 Hz
200 - 600 A ± (1,9 % of reading + 5 digits)
for frequency range 40 - 400 Hz