EN
Introduction
Thank you for purchasing this Triton product. This manual contains information
necessary for safe and effective operation of this product. This product has unique
features and, even if you are familiar with similar products, it is necessary to read
this manual carefully to ensure you fully understand the instructions. Ensure all users
of the product read and fully understand this manual. Keep these instructions with
the product for future reference.
Description of Symbols
The rating plate on your tool may show symbols. These represent important
information about the product or instructions on its use.
Wear hearing protection.
Wear eye protection
Wear breathing protection
Wear head protection
Wear hand protection
Read instruction manual
Toxic fumes or gases!
LASER warning!
Be aware of kickback!
Warning: Sharp blades or teeth!
DO NOT use in rain or damp environments!
Class II construction (double insulated for additional protection)
Environmental Protection
Waste electrical products should not be disposed of with
household waste. Please recycle where facilities exist. Check
with your local authority or retailer for recycling advice.
Conforms to relevant legislation and safety standards.
Caution!
Always disconnect from the power supply when adjusting,
changing accessories, cleaning, carrying out maintenance and
when not in use!
Do not touch the blades before the machine is disconnected
from the supply and the blades have come to complete stop.
Dust extraction required or recommended
Technical Abbreviations Key
V
Volts
~, a.c.
Alternating current
⎓ , d.c.
Direct current
A, mA
Ampere, milli-Amp
Ah
Amp hours (battery capacity)
W, kW
Watt, kilowatt
Hz
Hertz
n
No load speed
0
°
Degrees
Ø
Diameter
min
Operations per minute
-1
m/min
Meters per minute
dB(A)
Decibel sound level (A weighted)
m/s
Metres per second squared (vibration magnitude)
2
tritontools.com
Specification
Model
Voltage
Power
No load speed:
Max depth of cut:
Max blade size:
Bore:
Blade thickness:
Tooth Thickness:
Supplied blade:
Turntable:
Mitre table angles:
Bevel cuts:
Cutting capacities:
Cross cut
Mitre cut at 45°
Bevel cut at 45° right
Bevel cut at 45° left
Compound cut:
(without removing the sliding fence)
Left bevel 33.9° x right mitre 45°
Left bevel 45° x left mitre 45°
Right bevel 33.9° x left mitre 45°
Right bevel 33.9° x right mitre 31.6°
Minimum cutting with hold-down
clamp
Ingress protection:
Laser Class:
Laser Wavelength:
Laser Output power:
Power Cord length:
Protection class:
Dimensions (L x W x H)
Weight:
As part of our ongoing product development, specifications of Triton products
may alter without notice.
Sound & vibration information
Sound pressure L
PA
Sound power L
WA
Uncertainty K
The sound intensity level for the operator may exceed 85dB(A) and sound
protection measures are necessary.
The sound intensity level for the operator may exceed 85dB(A) and sound protection
measure are necessary.
WARNING: Always wear ear protection where the sound level exceeds 85dB(A)
and limit the time of exposure if necessary. If sound levels are uncomfortable, even
with ear protection, stop using the tool immediately and check the ear protection is
correctly fitted and provides the correct level of sound attenuation for the level of
sound produced by your tool.
WARNING: User exposure to tool vibration can result in loss of sense of touch,
numbness, tingling and reduced ability to grip. Long term exposure can lead to a
chronic condition. If necessary, limit the length of time exposed to vibration and use
anti-vibration gloves. Do not operate the tool with hands below a normal comfortable
temperature, as vibration will have a greater effect. Use the figures provided in the
specification relating to vibration to calculate the duration and frequency of operating
the tool.
WARNING: The vibration emission during actual use of the power tool can differ
from the declared total value depending on the ways in which the tool is used. There
is the need to identify safety measures to protect the operator that are based on an
estimation of exposure in the actual conditions of use (taking account of all parts of
the operating cycle such as the times when the tool is switched off and when it is
running idle in addition to the trigger time).
Original Instructions
TCMS254
230V~ 50Hz
1800W (S6: 20% 10mins)
3200min
-1
89mm
Ø254mm
Ø 30mm
1.8mm
2.6mm
Ø254mm; Ø30mm; 60T
Ø 279mm
0° to 50° left & right (0, 15, 22.5,
31.6, & 45° click stops)
0° to 47° left / 0° to 45° right (0,
33.9, 45° left)
64 x 318mm
64 x 222mm
25 x 318mm
40 x 318mm
55 x 215mm
40 x 215mm
40 x 215mm
40 x 260mm
179 x 53 x 3mm
IPX0
1M
400–635nm
1mW
1.8m
612 x 819 x 415mm
20.9kg
77.2dB(A)
88.2dB(A)
3dB(A)
8