Appendix A: Standards - Elcometer 266 Manual Del Usuario

Ocultar thumbs Ver también para 266:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 134

APPENDIX A: STANDARDS

The voltage calculator included in the Elcometer 266 DC Holiday
Detector is programmed with the following standards:
ASTM G6-83
ASTM G62-87
AS3894.1:F1 1991
AS3894.1:F2 1991
Other standards which do not derive the test voltage directly from the
coating thickness are not available within the Voltage Calculator
function. Testing to these standards is still possible however, by
setting the test voltage manually - see Section 9.2 'Manually Setting
the Voltage' on page en-18.
The Elcometer 266 DC Holiday Detector can be used in accordance
with the following list of standards and test methods:
Standard or
Method
Date
Number
ANSI/AWWA
1990
C214-89
ANSI/AWWA
1992
C214-89
AS3894.1
1991
ASTM D4787
1988
Elcometer 266 Voltage Setting: VC = Voltage Calculator; M = Manual
en-35
R
AS3894.1:F3 1991
AS3894.1:F4 1991
ANSI/AWWA C213-91
EN14430:2004
Title
Tape coating systems for
the exterior of steel water
pipes
Fusion-bonded epoxy
coating for the interior and
exterior of steel water
pipes
Site testing of protective
coatings. Method 1: Non-
conductive coatings -
Continuity test - High
voltage (brush) method
Continuity verication of
liquid or sheet linings
applied to concrete
NACE SP0188-2006
NACE SP0490-2007
NACE RP0274-04
Notes
Minimum voltage is 6 kV.
Use NACE RP0274
.
V = 525
Thickness (mil)
Testing coatings >150µm at
voltages >500 V
V =
.
250
Thickness (µm) / factor
High voltage (above 900 V)
test. Set voltage below
dielectric breakdown
strength of lining. Move
probe at 0.3m/s (1 ft/s) max.
www.elcometer.com
Voltage
Setting
M
VC, M
VC, M
M

Publicidad

Tabla de contenido
loading

Tabla de contenido