1.3 LCD icons 
1. Hot water available 
The  icon  indicates  that  the  domestic  hot  water  temperature  reaches  the  set  point.  The  hot  water  is  available  for  use.  Heat 
pump is standby. 
2. Fan ventilation   
The icon indicates that the fan ventilation function is enabled. 
By  pressing  the 
  button  and  hold  it  for  several  seconds  the  fan  ventilation  function  can  be  enabled  or  disabled.  If  this 
function is enabled the fan will continue working to ventilate the air, when the water temperature reaches the set point and 
unit  is  standby.  If  this  function  is  disabled  the  fan  will  stop,  when  the  water  temperature  reaches  the  set  point  and  unit  is 
standby. 
3. Electrical heating 
 
The  icon  indicates  that  the  electrical  heating  function  is  enabled.  The  electrical  heater  will  work  according  to  the  control 
program. The icon flashes during a disinfection cycle. 
4. Defrosting 
 
The  icon  indicates  that  the  defrosting  function  is  enabled.  This  is  an  automatic  function,  the  system  will  entry  or  exit  the 
defrosting according to the inner control program. The defrosting parameters cannot be changed at fieldwork. And the unit 
does not support manual defrosting control. 
5. Heating 
 
The icon indicates that the current operation mode is heating. 
6. Key lock 
 
The icon indicates the key lock function is enabled. The keys cannot be operated until this function is disabled. 
7. Left temperature display  
The display shows the setting water temperature. 
When checking or adjusting the parameters, this section will display the relating parameter number. 
In case any malfunction occurs, this section will display the related error code. 
8. Right temperature display  
The display shows the current downside temperature of the water tank. 
When checking or adjusting the parameters, this section will display the related parameter value. 
9. Time display  
 
The display shows the clock time or timer time. 
10. Timer 'ON' 
 
The icon indicates that the timer 'ON' function is enabled. 
11.  Timer 'OFF'   
The icon indicates that the timer 'OFF' function is enabled. 
12. Error 
 
The icon indicates there is malfunction. 
1.4 MAIN LOGICS 
1.4.1 Water temperature difference for compressor starting 
Parameter 1 "water temp. difference TS6" is used to control the compressor on or off. 
When  down  tank  temperature  T2  is  lower  than  setting  temperature  TS1‐TS6,  the  compressor  will  work  to  heat  the  water  until 
reaching the setting temperature TS1. 
 
 
 
 