The Digital Control Board system is an intricate and valuable piece of technology. For protection from power surges and electrical
shorts, consult the wire diagram below to ensure your power source is sufficient for the operation of the unit.
PB – ELECTRIC REQUIREMENTS
110-120V, 60Hz, 250W, 3-PRONG GROUNDED PLUG
NOTE: Electrical components, passed by product safety testing and certification services, comply
with a testing tolerance of ± 5-10 percent.
Locate and remove the four screws of the
electric wire shield on underside of unit.
FUEL INPUT RATING:
3.3 LB/H (1.5 KG/H)
INDEX
K : BLACK
W : WHITE
R : RED
Y : YELLOW
P : PURPLE
G : GREEN
ELECTRICAL WIRE DIAGRAM
CONTROL
BOARD
GROUNDED
POWER CORD
GROUND
W
IGNITOR ASSEMBLY /
HD CARTRIDGE HEATER
120V, 200W,
0.375" X 5.000" / 9.5 X 127 MM
AUGER MOTOR
& FEED SYSTEM
120V, 60Hz,
2 RPM MOTOR
Locate and remove the thirteen screws
that secure the hopper.
K
W
P
W
R
Y
R
GRILL PROBE
K
R
Y
DRAFT FAN
120V, 60Hz,
1 PHASE
K(Black)
W(White)
R(Red)
Y(Yellow)
P(Purple)
O(Orange)
G(Green)
27