Pump head 5 l/h and 11 l/h
5
3
2
1
A
Fig. 93: Replacing the diaphragm and pump head
A
Adhesive label: Tightening torque of metering head
screws
1
Cover plate
2
Metering head screws (4 pcs.)
3
Pump head
4
Suction valve
1.
Unscrew the suction and pressure valves (items 4 and 5).
2.
Remove the cover plate (item 1) on the metering head.
3.
Loosen the metering head screws (item 2).
4.
Remove the pump head (item 3).
5.
Take out diaphragm (5) and intermediate plate (6).
6.
Remove the protective diaphragm (7) from the plunger.
7.
Fit new protective diaphragm in the correct position.
8.
Reverse this procedure for re-installation.
9
7
6
8
10
4
11
169
5
Pressure valve
6
Diaphragm
7
Intermediate plate
8
Diaphragm rupture drain
9
Protective diaphragm
10 Vent screw