8 Help in the case of faults
56
Overheating
The string inverter interrupts the power fed to the grid if its
internal temperature is too high. Beforehand, the inverter
switches the installed fan so that the electronics are cooled
and protected. If fan cooling is insufficient, it then switches
off. According to past experience, this may occur in an
ambient temperature of +60 °C or higher.
| T > +60 °C
The string inverter interrupts the power feed to the grid. It
switches off.
| T < +60 °C
If the ambient temperature drops back below the +60 °C
threshold and the internal temperature is also reduced
below its critical point, the inverter switches back on
automatically.
Fault current monitoring
The fault current monitoring system automatically switches
the inverter off when a fault arises. Once the fault is rectified,
the inverter automatically switches on again after 4 minutes.
8.1

Messages on the LED indicators

The Fault LED indicator may light up or flash quickly or
slowly.
| The Fault LED indicator is lit
Inverter detects a probable irreversible fault and switches
off.
| The Fault LED indicator flashes slowly
LED display flashes at regular intervals
Inverter probably detects a reversible, temporary fault and
switches off temporarily. It normally switches back on
automatically once the fault has been cleared.
| The Fault LED indicator flashes quickly
LED display flashes briefly every 2 seconds
The inverter detects a reduction in output, for instance,
due to the temperature being too high.
Operating manual
Conergy IPG T series

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ipg 8 tIpg 11 tIpg 15 t

Tabla de contenido