Results Of The Legal Tests; Noise Level; Vibration Level; General Precautions - CAMPAGNOLA POWER ECO Manual De Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 29
2 – Power unit POWER 12
8000.0085 = POWE.0123
2.1.2

Results of the legal tests

NOISE LEVEL

1) Continuous A-weighted sound pressure level at the operator's position (LpA) and sound power level of the
tool (LwA), both measured according to standard UNI EN ISO 3746:
Tool combination

VIBRATION LEVEL

2) Root mean square weighted hand-arm acceleration frequency to which the user is exposed, measured ac-
cording to EN ISO 5349/1-2:
Tool combination
ELECTROMAGNETIC COMPATIBILITY LEVEL
3) The equipment complies with the electromagnetic compatibility directive 2014/30/EU.
2.2

General precautions

Do not use the tool indoors or in case of a potentially explosive environment.
Page 20
3 – Fixed long pole
4 – Telescopic long pole
LpA
1 – 3 - 5
1 - 4 - 5
1 - 3 - 6
1 - 4 - 6
1 - 3 - 7
1 - 4 - 7
1 - 3 - 8
1 - 4 - 8
2 - 3 - 9
2 - 4 - 9
1 - 3 - 5
1 - 4 - 5
1 - 3 - 6
1 - 4 - 6
1 - 3 - 7
1 - 4 - 7
1 - 3 - 8
1 - 4 - 8
2 - 3 - 9
2 - 4 - 9
Sound level UNI EN ISO 3746
LwA
eq
73.2
73.2
72
72
70.5
70.5
75
75
77
77
Vibrations level a
EN ISO 5349/1-2
heq
3.71 m/s
2
3.71 m/s
2
3.15 m/s
2
3.15 m/s
2
8.17 m/s
2
8.17 m/s
2
6.69 m/s
2
6.69 m/s
2
9.36 m/s
2
9.36 m/s
2
Use and Maintenance Manual – Translation of
Original Instructions Rev.: 03, Date 30/11/2021
9 – Elektra Head
87
87
86
86
87
87
92
92
93
93

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Power 12

Tabla de contenido