6.1.2
Cleaning and storing the tool
Proceed as follows:
•
Turn the ON-OFF switch (7) to off (pos. OFF).
•
Disconnect the power cable (14) from the battery and from the tool.
•
Disassemble the power unit from the extension pole and open the shells.
•
Clean inside the shells, removing the impurities that have entered the motor cooling fins. Refit by carrying out the
steps in inverse order, taking care to reposition the electronic board, connectors and connection wires correctly to
prevent damage.
6.1.3
Replacing the fuse
Proceed as follows:
•
Turn the ON-OFF switch (7) to off (pos. OFF).
•
Disconnect the power cable (14) from the battery and from the tool.
•
Loosen the screw cap of the fuse holder and replace the faulty fuse.
•
Tighten the cap back on the fuse holder.
6.1.4
Maintenance on the harvesting head
All the instructions to perform maintenance on the harvesting head are given in the specific manual, according to the
relevant model.
6.2
Extraordinary maintenance
Any extraordinary maintenance (example: replacing the gearmotor unit or electronic boards) must be per-
formed at an Assistance Centre authorised by the Manufacturer.
AUTHORISED WORKSHOP
The workshop authorised to carry out repairs on the Manufacturer's products.
6.3
Maintenance table
MAINTENANCE
Check that the screws are tightened correctly.
Check that the cooling slots are clean.
Check that the cable and connectors are intact.
Overhaul to be carried out at an Authorised Assis-
tance Centre.
Page 26
ROUTINE
X
X
X
Use and Maintenance Manual – Translation of
Original Instructions Rev.: 03, Date 30/11/2021
EXTRAORDINARY
X