Operation
• When the engine starts, move choke knob to "1/2 Choke" position
until the engine runs smoothly and then fully in to the "Run" position.
If engine falters, move choke knob back out to "1/2 Choke" position
until the engine runs smoothly and then to "Run" position.
If engine fires, but does not continue to run, move choke lever to "Full
Choke" and repeat starting instructions.
IMPORTANT: Do not overload the generator. Also, do not overload
individual panel receptacles. These outlets are protected against overload
with push-to-reset-type circuit breakers. If amperage rating of any circuit
breaker is exceeded, that breaker opens and electrical output to that
receptacle is lost. Read "Don't Overload the Generator" carefully.
Figure 19 - Full Choke Position
2.9
STOPPING THE ENGINE
• Shut off all loads, then unplug the electrical loads from generator panel
receptacles. Never start or stop the engine with electrical devices
plugged in and turned on.
• Turn "Off" the Idle Control switch (if on).
• Let engine run at no-load for several minutes to stabilize the internal
temperatures of engine and generator.
• Move Start/Run/Stop switch to "Off" position.
• Close fuel valve.
2.10 AUTOMATIC IDLE CONTROL
This feature is designed to greatly improve fuel economy. When this switch
is turned "On," the engine will only run at its normal fast governed engine
speed when electrical load is connected. When the load is removed, the
engine will run at a reduced speed of 2100 RPM. With the switch "Off,"
the engine runs at the normal fast engine speed all the time. Always have
the switch OFF when starting and stopping the engine.
12
Netzerotools.com
NOTE:
Netzerotools.com
2.11 COLD WEATHER OPERATION/DE-ICER
Under certain weather conditions (temperatures below 40° F (4° C) and a
high dew point), the engine may experience icing of the carburetor and/or
the crankcase breather system. To eliminate this problem, this generator
engine is fitted with a winter/summer valve. This directs hot air into the
carburetor during cold weather operation. Always make sure the winter/
summer valve is in the correct location relative to the weather conditions.
2.12 LOW OIL PRESSURE SHUTDOWN
SYSTEM
The engine is equipped with a low oil pressure sensor that shuts down
the engine automatically when the oil pressure drops below 10 psi. If the
engine shuts down by itself and the fuel tank has enough gasoline, check
engine oil level.
2.12.1 INITIAL START-UP
A delay built into the low oil shutdown system allows oil pressure to build
during starting. The delay allows the engine to run for about 10 seconds
before sensing oil pressure.
2.12.2 SENSING LOW OIL PRESSURE
If the system senses low oil pressure during operation, the engine shuts
down.
2.12.3 RESTARTING
If trying to restart the engine within 10 seconds after it shuts down, the
engine may NOT start. The system needs five (5) to 10 seconds to reset.
If the engine is restarted after such a shutdown and the low oil pressure
has not been corrected, the engine will run for about 10 seconds as
described above and then stop.
2.13 CHARGING A BATTERY
Storage batteries give off explosive hydrogen
gas while recharging. An explosive mixture will
remain around the battery for a long time after
it has been charged. The slightest spark can
ignite the hydrogen and cause an explosion. Such
an explosion can shatter the battery and cause
blindness or other serious injury.
Do not permit smoking, open flame, sparks or
any other source of heat around a battery. Wear
protective goggles, rubber apron and rubber
gloves when working around a battery. Battery
electrolyte fluid is an extremely caustic sulfuric
acid solution that can cause severe burns. If spill
occurs flush area with clear water immediately.
This generator has the capability of recharging a discharged 12 Volt
automotive or utility style storage battery. Do not use the unit to charge
any 6 Volt batteries. Do not use the unit to crank an engine having a
discharged battery.