DIMENSIONS (mm)
1 6
00
3
1. GATE ARRANGEMENT
Before starting the installation check if all the gate parts (fixed
and mobile) have a strong and as less as possible deformable
structure, also make sure that :
a) The leaf is rigid and compact;
b) The inferior slideway is perfectly straight, horizontal and
without any obstacles which could obstruct the gate sliding;
c) The inferior sliding wheels are equipped with greasable or
water tightened bearings;
d) The superior slideway has been produced and placed in the
manner that the gate is in a perfect vertical position;
e) Mechanical stops are always installed in order to avoid
possible derailment of the leaf.
2. FOUNDATION PLATE ANCHORING
For the installation of the foundation plate you have to:
2.1. Prepare a concret basement with the dimensions shown in
Fig. 1 (only Mercury 24V) and Fig. 2 (only Mercury 230V) where
the foundation plate and the anchoring bolts will be cemented.
NOTE: It is recommended (gate structure permitting) to lift the
foundation plate about 50 mm from the ground, in order to avoid
eventual water stagnation.
Fig. 1
ONLY 24V VERSION
67411230
®
0
3 0 0
DIMENSIONS (mm)
Fig. 2
ONLY 230V VERSION
2.2. Before cementing the plate insert a flexible plastic duct of at
least 30mm in diameter into the special hole of the plate.
2.3. Before cementing the plate, make sure that it's perfectly
leveled and that the distance of 63-68 mm as shown in Fig. 3 is
respected.
3. CABLES PASSAGE ARRANGEMENT
Mercury is provided with seven holes for electric cables
passage.
Important: Always run mains carrying cables (230V
holes to low voltage cables ( 24V) Fig. 4.
Plinth
4. FITTING OF THE MOTOR
4.1. Insert the 4 grub screws into the special holes for the
adjustment of the motor height on the plate (Fig. 5).
At the end of installation check if the 4 grub screws are well
gripped on the foundation plate.
DIMENSIONS (mm)
MINIMUN DIMENSION Q
Z16
100 mm
Z20
108 mm
63-68 mm
ENGLISH
Plinth
62 mm
Fig. 3
inseparate
~)
Fig. 4
9