27
• Note On­Screen instructions and select the "NEXT" button
• Select "FINISH"
WINDOW CALIBRATION
NOTE: Vehicles equipped with the auto up feature must have the windows calibrated after a battery disconnect.
NOTE: The door must be completely closed when starting this step.
1. Sit in the driver seat and close the door.
2. Lower the window part of the way down.
3. Run the window to the full up position and continue to hold the switch for an additional two seconds.
4. Run the window to the full down position and continue to hold the switch for an additional two seconds.
5. Raise the window to the full up position.
6. Repeat the steps for the remaining windows.
UPDATE PRESSURE THRESHOLDS
NOTE: The wiTECH software level must be at the latest release to perform this procedure.
NOTE: The vehicle must be driven before the TPMS light will turn off.
CAUTION: Read all notes and cautions for programming procedures.
NOTE: Have the vehicle PIN readily available before running the routine
1. Connect a battery charger to the vehicle.
2. With the wiTECH diagnostic application, perform the following steps:
• Select "WIRELESS CONTROL MODULE (WCM)"
• Select the "MISCELLANEOUS FUNCTIONS" tab
• Highlight and select "UPDATE PRESSURE THRESHOLDS"
• Note On­Screen instructions and select the "NEXT" button
• Verify current settings, select the "NEXT" button to change settings
• Select "NEXT"
• Enter the PIN when prompted.
• Select "NEXT"
• Verify that the PIN number is correct
• Once verified, select "NEXT"
• Select "NEXT"
• Wait for the WCM to update it's configuration
• Once the WCM configuration is complete, select "NEXT"
• Note On­Screen instructions and select the "FINISH" button
TEMPORARY REMOTE START DISABLE
NOTE: The wiTECH software level must be at the latest release to perform this procedure.
CAUTION: Read all notes and cautions for programming procedures.
1. Connect a battery charger to the vehicle.
2. With the wiTECH diagnostic application, perform the following steps:
• Select "WIRELESS CONTROL MODULE (WCM)"
• Select the "MISCELLANEOUS FUNCTIONS" tab
• Highlight and select "TEMPORARY REMOTE START DISABLE"
• Note On­Screen instructions and select the "NEXT" button
• Select the "DISABLE" button to activate the remote start function
• Select "YES" to reset the module and exit the routine, select "NO" to toggle the value back
• Select "FINISH"
CLEAR ALL DTC'S
NOTE: The wiTECH diagnostic application is the preferred method for clearing all DTC's.