WARNING: This pump is designed for indoor installation only. Failure to install indoors will sidnificantly
increase the risk of injury or death from electrical shock.

PRE-INSTALLATION

APPLICATION
This unit is a convertible jet pump designed for pumping water where the water level is up to 90ft for 3/4HP or 110
ft. for 1HP.
For wells 25 ft. or less in depth, shallow well installations should be adapted. The shallow well installations
have only one single pipe between the pump and well water.
system built into the nose of the pump.
For wells 25 ft. to 110 ft. in depth, deep well installation should be adapted. In this type of setup, the nozzle &
venturi are put into an ejector package or "jet kit" that gets placed down in the well. There are two pipes going to
well. One pipe pulls the water up (suction) while the other pipe pushes some water down (drive) to circulate water
through the nozzle and venturi. Water moving through that nozzle & venturi makes a pressure differential that
helps bring the water up to the pump.
A pressure switch pre-set at 30 psi "on"/ 50 psi "off" has been installed on the pump. The pressure switch will
automatically turn the pump on and off based on the system pressure.
TOOLS REQUIRED
Flathead
Screwdriver
Safety
goggles
SPECIFICATIONS
POWER SUPPLY
LIQUID TEMP. RANGE
DISCHARGE SIZE
SUCTION SIZE
SHALLOW WELL WATER LEVEL
DEEP WELL WATER LEVEL
DETERMINE THE DEPTH OF YOUR WELL
Tie a small but heavy weight to the end of a piece of string. Lower the weight into the well until it reaches the bottom.
Make a mark on the string at ground level. Pull the weight out of the well and measure from the bottom of the weight to
the ground level mark. This is the depth of your well. This number should not exceed the maximum rated depth for your
pump. If it does, it will greatly hinder or prevent the proper operation of the pump.
LOCATION OF THE PUMP
Decide on the area for the pump installation. Select a pump location with adequate space for future pump maintenance.
Intended for indoor use only, it can be located in the basement or utility room of the house. If installed outside of the
house, it should be protected by a pump house with auxiliary heat to prevent possible freezing. Protect pump from direct
weather elements such as sun, rain, sleet, snow, and extreme temperature changes. The well also should be protected
for sanitary reasons. Mount the pump as close to the well as possible.
For Professional Technical Support call 1-844-242-2475
Phillips
Screwdriver
Tape
Measure
115V/230V, 60 HZ., 20/15 Amp Circuit (3/4HP).
25/15 Amp Circuit (1HP)
32°F to 95°F (0°- 35°C)
1 in. FNPT
1-1/4 in. FNPT
25 ft.
WPD07502K/ WPD07501K max. 90 ft.
WPD10001K max. 110 ft.
A shallow well jet pump has the nozzle & venturi of the jet
Pipe wrench
Thread
Tape
Hacksaw
3