If no key is pressed within 15 seconds during programming, it
automatically exits the programming mode.
ATTENTION: If the values of the programming
menu A0 to A4 are changed, the load switch-off no
longer provides any protection! Teach the door operator in
again before re-commissioning. For this carry out
the door operator (Chapter 15) .
Menu
Function, setting range, unit
A0 Length SOFT RUN OPEN in 7cm
000..009
A1 Length SOFT RUN CLOSE in 7cm
000..009
A2 Soft running speed (CLOSE) mm/s
000= 50...009= 140
A3 Backjump, OFF= 000 ON= 001
A4 Change in direction, OFF= 000 ON= 001
Setting (with +/-) only possible if EMERGENCY
STOP plug (1, green) is unplugged.
1)
A5 Added load OPEN
1)
A6 Added load CLOSE
A7 Door type: Overhead sectional door/one-piece
door = 000
Side sectional door* = 001
Side sectional door with soft start = 002
* Obstruction release also in OPEN direction
If A7 was changed, perform a reset
and then teach in the door operator again.
(Chapter 15).
A8 Warning time (OPEN/CLOSE) 001=2sec...
008=16sec
A9 Accessory card
000= ZKMagicS
001= ZKMagic
b0 Relay 1 (with ZKMagic accessory card)
000= no function
001= E-lock
002= warning light*
003= photo cell test* (interruption transmitter
voltage)
004= status display*: Door in end position OPEN
005= status display*: Door in end position
CLOSED
006= green light*
007= red light*
* if A9= 001
16 / 219
Teaching in
Factory setting
000..009
000..009
(Chapter 19)
b1 Relay 2 (with ZKMagic accessory card)
000= no function
001= E-lock*
002= warning light*
003= photo cell test* (interruption transmitter
voltage)
004= status display*: Door in end position OPEN
005= status display*: Door in end position
CLOSED
006= green light*
007= red light*
* if A9= 001
b2 Closing edge protection, for accessory card
ZKMagic and if A9= 001
000= OFF
b3 Empty run detection 000= OFF 001= ON
b4 Automatic closing
000= OFF
001.0.010 keep-open time secs.*
(001 = 5secs... 010 = 50secs)
011..040 keep-open time min*
(011=1min... 040=30min) * plus warning time
* only active if door was fully opened
b6 Maintenance interval
000= OFF
001..009 (1,000 door movements)
002
Example: 005 = 5,000 door movements
The operator lighting flashes after every door
004
movement when the maintenance interval has run
out. A misadjustment resets the counter of the
005
maintenance interval.
b7 Version number
001
Each of the digit positions (0-7)
000
is displayed in turn.
The example shows:
Version: 04 Date: 20.05.10
003
Select the position with the pushbuttons
003
b8 Service mode
000
000= control panel free, menu items adjustable
001= control panel locked, menu items not
adjustable
002= data output (accessory card)
Setting only possible if EMERGENCY STOP plug
(1, green) and photo cell (2, yellow) are
unplugged.
b9 Run counter (not adjustable)
Each of the digit positions (0-5)
000
is displayed one after another.
The example shows the value
000
8,000
Select the position with the pushbuttons
000
C0 Test mode for Magic-Door-Control (option)
Radio signal, maximum 15 seconds:
000= no signal
001= end position OPEN
002= end position CLOSED
003= run open
004= run close
005= standstill underway
007= error
008= obstruction
C1 Automatic closing from partial opening
secs and mins
000= OFF
001.010 keep-open time secs.*
(001 = 5secs... 010 = 50secs)
011..040 keep-open time min*
(011=1min... 040=30min) * plus warning time
C2 Partial opening in 5cm steps 000..100
C3 Lighting time, after motor running
000..060 (10sec. steps)
IP2286 12/2017
001= OSE
002= 8k2
1)
*, secs. and min.
04200510
01234567
008000
012345
1)
000
000
001
000
000
and
.
000
and
.
000
000
020
012
Magic 1000-2