Causes Of Errors/Remedies; Display / Check Radio Level; Changing The Battery Of The Remote Transmitter; Maintenance Intervals - Normstahl Magic 1000-2 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 136
002
EEprom data
003
Current measurement
004
Hardware Photo cell
005
Switch off thyristors
006
Switch off relay
007
Watchdog test
008
ROM test
009
RAM test
010
SD test
Troubleshooting: Reset (Chapter 19) and then perform work
step Teaching in the door operator (Chapter 15).
If the error occurs again, request customer service.
Note: If the same error occurs in two successive self-tests,
the control system will be disabled (commands are rejected).
After approximately one further minute, the system runs
another self-test. If no errors are detected, the control system
is enabled again. If the error persists, a reset will need to be
performed. This will delete all settings and the door operator
will have to be taught in again.

Causes of errors/Remedies

Description
Possible cause/Remedy
Door operator light
The door has hit an obstruction, do
flashes evenly
function test
Door operator light
Door operator is not taught in,
flashes at intervals of
attention no protection by load
4
switch-off! Carry out door operator
Teaching in the door operator
(Chapter 15)
Entrapment
Incorrect setting of door or
protection device not
entrapment protection device /
working.
Reset and teach in again
The operator is not
None or wrong voltage supply / The
working at all.
fuse of the motor control is defective
/ Check external terminals 7 and 8.
The operator is
The slides are not snapped-in
defective.
properly./The toothed belts are not
tensioned correctly./The door
thresholds are frozen.
Operator closes the
Operator teaches in the travel
door slowly (soft
automatically. After CLOSED end
start) whilst door
position, moves automatically to
operator light flashes
OPEN end position. If the door
operator light flashes in intervals of
4, carry out Teaching in the door
operator (Chapter 15)
The operator
Check that the door is running
switches off during
smoothly and that the entrapment
motion.
protection device is working properly
/ Reset / Teach in the door operator
Remote transmitter is
Replace the batteries
not working, LED not
alight
Remote transmitter is
If the function message assigned to
not working
the transmission pulse is not
displayed whilst the transmitter is
actuated (see Chapter 16): Teach in
remote transmitter / Poor reception
(install optional antenna)
The operator cannot
Check the wall keypad and control
be used via the wall
wire.
keypad (optional).
The operator cannot
Radio level too weak. There are
be used via the
interfering radio signals from other
remote transmitter
transmission sources / Carry out
(optional).
radio level check as described below
18 / 219

Display / check radio level

The signal strength of the received radio signal can be
displayed, for this:
• During one of the 3 status messages A, B or C (see Chapter
10), press the pushbuttons
(approx. 1 s), F0 flashes in the display.
• Press the two buttons again simultaneously
(approx. 1 sec), the radio level display is activated.
x=1 no radio signal ...x=8 high signal strength
The radio level display remains activated until the two buttons
are pressed again simultaneously (approx. 1 sec.).
Changing the fuse
Pull out mains plug.
• Remove the operator hood, see page 219.
• Remove the faulty fuse (S1) from the fuse holder (S2) and
replace it. Make sure that the new fuse has the correct
value!
• Replace the operator hood.
Restore the mains connection.
Changing the battery of the
remote transmitter
Open the housing cover. Remove the
battery, fit a new one and replace the
housing cover.
Use only leak-proof batteries.
Make sure the polarity is correct. Dispose of used
batteries in an environmentally-friendly way.

23 Maintenance intervals

Monthly
• Load switch-off (entrapment protection device)
• Emergency lock release
• Additional safety devices (if fitted)
Every 6 months
• Mounting of door operator on the ceiling and on the wall

24 Declaration of incorporation

Declaration of incorporation see page 189.

25 Technical data

Mains connection
Device fuse
Power consumption at rated load
Closed current
Degree of protection
Wireless remote control
Einlernbare Handsenderbefehle
Remote transmitter range 1)
Remote transmitter batteries
Idle speed
Traction
Rated load
IP2286 12/2017
and
simultaneously
230 V~, 50/60 Hz
2x 1.6 A, T (slow-blow)
170 W
< 2 W
For dry rooms
only, IP 20
Protection class 1
868.35 MHz AM,
AES-128 Encrypted
15 - 50 m
CR 2032 (3 V)
~ OPEN >210 mm/s
~ CLOSE >140 mm/s
1,000 N
300 N
Magic 1000-2
50

Publicidad

Tabla de contenido
loading

Productos relacionados para Normstahl Magic 1000-2

Tabla de contenido