Restart Cleaning Module:
To restart the cleaning module, press keys 1,2 and 4 for seven seconds.
4.5.1

Alarm - Water valve

If the mixing container will be filled at beverage mode, a slashed faucet symbol is
displayed and the display will flash between green and blue.
If there is a active fault message a further slashed faucet is displayed the display will flash
between red and blue.
Fig. 26: Alarm - Water valve
4.5.2

Alarm - Alarm - Error: Compressor

Fig. 27: Alarm level - ERROR: Compressor
1
Current consumption to high at start.
2
Compressor runs continuously for 15 min.
3
Compressor running time higher than 75 % in one hour.
Ä Chapter 6.2.1 'Display error messages and incidents' on page 32, Fig. 33.
See
4.5.3

Alarm - No Cleaning

If the 'Beer Cut' time is exceeded, an alarm is displayed and the 'Beer Cut' activated.
Cleaning must be carried out.
Fig. 28: Alarm level - No Cleaning for 21 days