Operation
5
Operation
CAUTION!
Only authorised, trained personnel are allowed to perform the following
activities
5.1
Switching on the Cleaning Module
Before switching on the unit, familiarise yourself with how to use the unit by reading these
operating instructions carefully.
On switching on the unit, the unit type and software version will be briefly displayed.
Then the unit will go into the operating mode saved when it was last switched off.
5.2
Starting the cleaning process
Start "Cleaning Mode":
5.3
Switching off the Cleaning Module in an emergency
CAUTION!
In an emergency, disconnect the mains plug from the power supply and secure
it against being switched back on again. We recommend unplugging the power
cable (IEC connector) at the rear of the unit
the water and electrical connections' on page 18, Fig. 2, Pos. 2 and keeping it
safe.
5.4
Changing the product container
CAUTION!
There is a risk of injury to skin and eyes caused by the product/the agent!
Injuries to skin and eyes can be caused by the product/the agent!
– Use validated products only.
– Handle the product carefully.
– Use personal protective equipment.
The safety measures and instructions of the safety data sheet accompanying
the product must be strictly followed.
The following protective equipment must be worn when changing the product
container:
n
Chemical resistant protective gloves
Chemical-resistant protective gloves are used to protect the hands against aggressive
chemicals.
Protective goggles
n
Protective eyewear protects the eyes against flying parts and liquid splashes.
Rev. 04-06.2018
Ä Chapter 2.5 'Personnel requirements' on page 12.
Ä Chapter 4.4.2 'Cleaning mode' on page 23
30
Ä Chapter 3.2 'Detailed look at