Fault table - Error correction

Fault
Cause
description
Water valve
Blocking of the water
valve due deposits or
contamination
prevents the closing of
the valve.
Restart Cleaning Module:
To restart the cleaning module, press keys 1,2 and 4 for seven seconds.
Fault
Cause
description
ERROR:
Compressor does not start - Starting current
Compressor
too high.. The display flashes, alternating
(Fig. 33)
between red and white.
Compressor runs for 15 mins in continuous
operation - Escaping air due to leak - Error in
the pressure sensor.
Compressor runs for 15 mins in continuous
operation - Escaping air due to leak - Error in
the pressure sensor.
No cleaning for ..
If the "Beer Cut" time is exceeded, an alarm is
days
displayed and the "Beer Cut" activated. If
(Fig. 34)
cleaning is not currently possible, an
additional day (+1) can be requested once.
The display flashes, alternating between red
and white.
Malfunction notifications and rectification
Remedy
Automatic:
The water valve will be activated shortly at several times
(4x) if the cleaning module recognize the fault (mixing
container is filled at serving mode).
Manual:
1. Stop water supply
2. Open Beer tap and drain mixing container
3. When the mixing container is emptry, restart water
intake.
If the water valve fault is displayed again restart
procedure with step 1. If the error message is repeated
after several retries dont close the water valve and send
the unit to repair.
33
Remedy
Restart the Cleaning Module.
If the error reoccurs, have the
unit repaired.
Check that the unit is leak-
tight. Check the pressure.
Check that the unit is leak-
tight. Check the pressure.
Cleaning must be carried out!
Rev. 04-06.2018