Handling And Storing The Product; Product Introduction; Applications; Pumped Liquids - Grundfos MAGNA3 D Instrucciones De Instalación Y Operación

Ocultar thumbs Ver también para MAGNA3 D:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6. Handling and storing the product

If the pump is not used during periods of freezing
temperatures, protect the pump and pipes from
freeze and burst damage.
Observe local regulations concerning limits for
manual lifting or handling.
Always lift directly on the pump head or the cooling fins when
handling the pump. For large pumps, it may be necessary to use
lifting equipment. See 3.3 Lifting the pump.

7. Product introduction

MAGNA3 is a complete range of circulator pumps with integrated
controller enabling adjustment of pump performance to the actual
system requirements. In many systems, this reduces the power
consumption considerably, reduces noise from thermostatic
radiator valves and similar fittings and improves the control of the
system.
You can set the desired head on the pump operating panel.

7.1 Applications

The pump is designed for circulating liquids in the following
systems:
heating systems
domestic hot-water systems
air-conditioning and cooling systems.
You can also use the pump in the following systems:
ground-source heat-pump systems
solar-heating systems.

7.2 Pumped liquids

The pump is suitable for thin, clean, non-aggressive and
non-explosive liquids, not containing solid particles or fibers that
may attack the pump mechanically or chemically.
In heating systems, the water must meet the requirements of
accepted standards on water quality in heating systems.
The pumps are also suitable for domestic hot-water systems.
Observe local legislation regarding pump housing
material.
We strongly recommend that you use stainless-steel pumps in
domestic hot-water applications to avoid corrosion.
In domestic hot-water systems, we recommend that you use the
pump only for water with a degree of hardness lower than
approximately 14 °dH.
In domestic hot-water systems, we recommend that you keep the
liquid temperature below 149 °F (65 °C) to eliminate the risk of
lime precipitation.
Do not pump aggressive liquids.
Do not pump flammable, combustible or explosive
liquids.
7.2.1 Glycol
You can use the pump for pumping water-ethylene-glycol
mixtures up to 50 %.
Example of a water-ethylene-glycol mixture:
Maximum viscosity: 50 cSt ~ 50 % water/50 % ethylene-glycol
mixture at 50 °F (-10 °C).
The pump has a power-limiting function that protects it against
overload.
The pumping of water-ethylene-glycol mixtures affects the
maximum curve and reduces the performance, depending on the
water-ethylene-glycol mixture and the liquid temperature.
To prevent the ethylene-glycol mixture from degrading, avoid
temperatures exceeding the rated liquid temperature and
minimize the operating time at high temperatures.
Clean and flush the system before you add the ethylene-glycol
mixture.
To prevent corrosion or lime precipitation, maintain the
ethylene-glycol mixture regularly. If further dilution of the supplied
ethylene-glycol is required, follow the glycol supplier's
instructions.
Additives with a density and/or kinematic viscosity
higher than those/that of water reduce the hydraulic
performance.
Max. 95 % RH
Enclosure Type 2
Fig. 15 Pumped liquids, flanged version
17