5.
Drive ½" (13mm) locking screws through frame holes into window sash (See Fig. 9 and Fig. 10).
Fig. 9
6.
To secure lower sash in place, attach right angle sash lock with 3/4" (19mm) or ½" (13mm) screw as
Shown. (See Fig.11).
Fig. 11
If AC is blocked by storm window
Add wood as shown in Fig. 13, or remove storm window before air conditioner is installed.
If storm window frame must remain in place, be sure the drain holes or slots are not caulked or painted
shut. Accumulated rainwater or condensation must be allowed to drain out.
Storm window
frame or other
obstruction
Sash
1 ½" Min
Board thickness
(38mm)
as required, for
proper pitch to
rear, along
entire sill.
Fasten with
nails or screws.
Fig.10
7.
Cut foam seal and insert in the space between the upper
and lower sashes (See Fig. 12) .
Removing AC from Window
Turn AC off and disconnect power cord.
Remove sash seal from between windows
and unscrew safety lock.
Remove screws installed through frame
and frame lock.
Close (slide) side panels into frame.
Keeping a firm grip on air conditioner,
raise sash and carefully "rock" air
conditioner backward to drain any
condensated water in the base of the unit.
Be careful not to spill any remaining water
while lifting unit from the window.