Installing The Product; Location - Grundfos KPC 24/7 210 Instrucciones De Instalación Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 33
1.1.2 Other important notes
A blue or grey circle with a white graphical
symbol indicates that an action must be
taken.
If these instructions are not observed, it
may result in malfunction or damage to the
equipment.
Tips and advice that make the work easier.

2. Installing the product

Observe local regulations setting limits for
manual lifting or handling.
CAUTION
Crushing of feet
Minor or moderate personal injury
- Use safety shoes when handling the
pump.

2.1 Location

The pump can be installed in a well or pond for
permanent or portable use in vertical position.
Make sure that there are minimum 3 m
free cable above the liquid level. This limits
the maximum installation depth to 7 m for
pumps with a 10 m cable and to 2 m for
pumps with a 5 m cable.
On
Max. 3 m
Min. 5 cm
Fig. 1
Location of KPC pump
6
Max. 40 °C / Min. 0 °C
Max. 7 m
< KPC 300A: 10 mm
< KPC 600A: 10 mm
2.1.1 Minimum space for the float switch
The pumps require 5 cm free space between the
float switch and the wall. The free space ensures
free movability of the float switch.
KPC 300 A
Fig. 2
Minimum pit dimensions for KPC 300 A
KPC 600 A
Fig. 3
Minimum pit dimensions for KPC 600 A

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Kpc 24/7 270Kpc 300 aKpc 600 a

Tabla de contenido